- Code: ZA:1
- Display: ZA:1
- Description: There is a big difference between the direction for the Z Motor and the position detected by the motor encoder.
- Causes: Z Motor is defective. There is a bad contact or a cut-line in the cable.
- Remedy: Replace the Z Motor. Check the cable connection or replace the cable.
- Code: ZA:14
- Display: ZA:14
- Description: ZA Servo CPU can't communicate with the Main CPU.
- Causes: There is a problem in the electric route between the Main CPU and the ZA Servo CPU.
- Remedy: Replace the Main board.
- Code: ZA:16
- Display: ZA:16
- Description: Error is detected with the ZA Servo CPU.
- Causes: Main board.
- Remedy: Replace the Main board.
- Code: ZA:5
- Display: ZA:5
- Description: There is a big difference between the direction for the A Motor and the position detected by the motor encoder.
- Causes: A Motor is defective. There is a bad contact or a cut-line in the cable.
- Remedy: Replace the A Motor. Check the cable connection or replace the cable.