- Code: n19
- Display: S driver overheat
- Description: Spindle motor driver becomes too hot.
- Causes: Big load has given to the A-axis continuously. Thermister of the Spindle motor driver IC is not operating correctly.
- Remedy: Check the milling condition. Replace the Spindle board.
- Code: n20
- Display: S power overload
- Description: Current to the Spindle motor driver becomes abnormal condition.
- Causes: Big load has given to the A-axis continuously.
- Remedy: Check the milling condition.
- Code: XY:1
- Display: XY:1
- Description: There is a big difference between the direction for the X Motor and the position detected by the motor encoder.
- Causes: X Motor is defective. There is a bad contact or a cut-line in the cable.
- Remedy: Replace the X Motor. Check the cable connection or replace the cable.
- Code: XY:14
- Display: XY:14
- Description: XY Servo CPU can't communicate with the Main CPU.
- Causes: There is a problem in the electric route between the Main CPU and the XY Servo CPU.
- Remedy: Replace the Main board.
- Code: XY:16
- Display: XY:16
- Description: Error is detected with the XY Servo CPU.
- Causes: Main board.
- Remedy: Replace the Main board.
- Code: XY:5
- Display: XY:5
- Description: There is a big difference between the direction for the Y Motor and the position detected by the motor encoder.
- Causes: Y Motor is defective. There is a bad contact or a cut-line in the cable.
- Remedy: Replace the Y Motor. Check the cable connection or replace the cable.