Catalog
-
Sign In
-
Contacts
-
Forum
-
Eng
Roland MDX540 Modela proII
Error Codes List page 1
|
|
- Code: FE:10
- Display: FE:10
- Description: Z Limit SW can not be detected.
- Causes: Z Limit SW is not attached correctly or defective. There is a bad contact or a cut-line in the cable.
- Remedy: Fix the Z Limit SW at the correct position. Replace the X Limit SW. Check the cable connection or replace the cable.
- Code: FE:11
- Display: FE:11
- Description: A Limit SW can not be detected.
- Causes: A Limit SW is not attached correctly or defective. There is a bad contact or a cut-line in the cable.
- Remedy: Fix the A Limit SW at the correct position. Replace the X Limit SW. Check the cable connection or replace the cable.
- Code: FE:12
- Display: FE:12
- Description: Phase signal or encoder of the X Motor becomes out of order in the initial operation.
- Causes: X Motor is defective. There is a bad connection or cut-line in the cable.
- Remedy: Replace the X Motor. Check the cable connections or replace the cable.
- Code: FE:13
- Display: FE:13
- Description: Phase signal or encoder of the Y Motor becomes out of order in the initial operation.
- Causes: Y Motor is defective. There is a bad connection or cut-line in the cable.
- Remedy: Replace the Y Motor. Check the cable connections or replace the cable.
- Code: FE:14
- Display: FE:14
- Description: Phase signal or encoder of the Z Motor becomes out of order in the initial operation.
- Causes: Z Motor is defective. There is a bad connection or cut-line in the cable.
- Remedy: Replace the Z Motor. Check the cable connections or replace the cable.
- Code: FE:15
- Display: FE:15
- Description: Phase signal or encoder of the A Motor becomes out of order in the initial operation.
- Causes: A Motor is defective. There is a bad connection or cut-line in the cable.
- Remedy: Replace the A Motor. Check the cable connections or replace the cable.