PrintCopy.info service

Xerox WorkCentre 5225

Error Codes List page 46

  • Code: 094-420
  • Description: BTR Unit Warning RAP The BTR reached end of life.
  • Remedy: Verify that the BTR Assembly is at end of life (Detailed Maintenance Activities). The BTR Assembly is at end of life. Y↓N→Replace the MCU PWB (PL 9.1). Replace the BTR Assembly (PL 2.6).
  • Code: 102-356
  • Description: Controller Software RAP An internal Controller error shut down the processor.
  • Remedy: Check the installation of the P-Kit/HDD-Kit/RAM boards. Reload Software (ADJ 9.3.1). Replace the ESS PWB (PL 9.2).
  • Code: 102-380
  • Description: UI Control RAP An internal UI controller error shut down the processor.
  • Remedy: Reload Software (ADJ 9.3.1). Replace the ESS PWB (PL 9.2).
  • Code: 102-381
  • Description: UI Data Link RAP During transmission between the ESS and the UI an initialization send error or a retrieve error for receiving data was detected by the ESS.
  • Remedy: Check the connection between the ESS and the UI. Pull out and insert or replace the DIMM (PL 9.2). Reload Software (ADJ 9.3.1). Replace the ESS PWB (PL 9.2) If the problem persists, replace the Control Panel UI PWB (PL 11.2).
  • Code: 102-382
  • Description: Application Layer Command RAP • The required parameters were not sent by the UI. • A length error was detected in the variable length parameter. • A confirmation message was not received within the specified time when a request message was sent to the UI.
  • Remedy: Pull out and insert or replace the DIMM (PL 9.2). Reload Software (ADJ 9.3.1). Replace the ESS PWB (PL 9.2).