PrintCopy.info service

Xerox WorkCentre 5225

Error Codes List page 1

  • Code: 003-318
  • Description: IIT Soft Failure RAP The IIT software is faulty
  • Remedy: Check the P/Js on the IIT/IPS PWB (PL 11.3). If the problem persists, reload Firmware (ADJ 9.3.1).
  • Code: 003-319
  • Description: IIT Video Driver Detection Failure RAP A Compression Threshold overflow, DMA Transfer error, or Other compression system errors were detected.
  • Remedy: Check the P/Js on the IIT/IPS PWB (PL 11.3). If the problem persists, reload Firmware (ADJ 9.3.1).
  • Code: 003-320
  • Description: IISS-ESS Communication Failure 1 RAP An abnormal parameter is set for the send function.
  • Remedy: Check the P/Js on the IIT/IPS PWB (PL 11.3). Check the P/Js on ESS PWB (PL 9.2). If the problem persists, reload Firmware (ADJ 9.3.1).
  • Code: 005-121
  • Description: CVT Feed Sensor On JAM RAP After the first-out feed operation started (Feed Motor On (CW)) in Duplex mode, the DADF Feed Out Sensor did not turn On within the specified time.
  • Remedy: Execute Component Control[005-205]. Actuate the DADF Feed Out Sensor (PL 15.6) with paper. The display changes. Y↓N→Check the connections of P/J769 and P/J758. P/J769 and P/J758 are connected correctly. Y↓N→Connect P/J769 and P/J758. Check the wire between J769 and J758 for an open circuit or a short circuit. The wire between J769 and J758 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P758-1 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P758-3 (+) and GND (-). Actuate the DADF Feed Out Sensor with paper. The voltage changes. Y↓N→Replace the DADF Feed Out Sensor (PL 15.9). Replace the DADF PWB (PL 15.3). Execute Component Control[005-001]. The DADF Feed Motor (PL 15.9) starts up. Y↓N→Check the connections of P/J764 and P/J754. P/J764 and P/J754 are connected correctly. Y↓N→Connect P/J764 and P/J754. Check the wire between J764 and J754 for an open circuit or a short circuit. The wire between J764 and J754 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P754-1 (+) and GND (-), and between P754-7 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Feed Motor (PL 15.9). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).
  • Code: 005-122
  • Description: CVT Simplex/Side1 Pre-Registration On JAM RAP • After the Pre Feed operation started for the first sheet (DADF Feed Motor On (CW)) in Duplex or Simplex mode, the Pre-Registration Sensor did not turn On within the specified time. • After the Pre Feed operation started for the second sheet onwards (DADF Feed Motor On (CW)) in Duplex mode, the Pre-Registration Sensor did not turn On within the specified time
  • Remedy: Execute Component Control[005-206]. Actuate the DADF Pre Registration Sensor (PL 15.7) with paper. The display changes. Y↓N→Check the connections of P/J781 and P/J761. P/J781 and P/J761 are connected correctly. Y↓N→Connect P/J781 and P/J761. Check the wire between J781 and J761 for an open circuit or a short circuit. The wire between J781 and J761 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P761-10 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P761-12 (+) and GND (-). Actuate the DADF Pre Registration Sensor with paper. The voltage changes. Y↓N→Replace the DADF Pre Registration Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Execute Component Control[005-001]. The DADF Feed Motor (PL 15.9) starts up. Y↓N→Check the connections of P/J764 and P/J754. P/J764 and P/J754 are connected correctly. Y↓N→Connect P/J764 and P/J754. Check the wire between J764 and J754 for an open circuit or a short circuit. The wire between J764 and J754 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P754-1 (+) and GND (-), and between P754-7 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Feed Motor (PL 15.9). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).
  • Code: 005-123
  • Description: CVT Simplex/Side1 Registration JAM RAP After pre-registration started (DADF Feed Motor On (CCW)), the Registration Sensor did not turn On within the specified time.
  • Remedy: Execute Component Control[005-110]. Actuate the DADF Registration Sensor (PL 15.7) with paper. The display changes. Y↓N→Check the connections of P/J782 and P/J761. P/J782 and P/J761 are connected correctly. Y↓N→Connect P/J782 and P/J761. Check the wire between /J782 and J761 for an open circuit or a short circuit. The wire between /J782 and J761 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P761-15 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P761-14 (+) and GND (-). Actuate the DADF Registration Sensor with paper. The voltage changes. Y↓N→Replace the DADF Registration Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Execute Component Control[005-001]. The DADF Feed Motor (PL 15.9) starts up. Y↓N→Check the connections of P/J764 and P/J754. P/J764 and P/J754 are connected correctly. Y↓N→Connect P/J764 and P/J754. Check the wire between J764 and J754 for an open circuit or a short circuit. The wire between J764 and J754 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P754-1 (+) and GND (-), and between P754-7 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Feed Motor (PL 15.9). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?