PrintCopy.info service

Toshiba e-Studio 3515AC

Error Codes List page 2

  • Code: C1B0
  • Description: LCF transport motor abnormality
  • Causes: Paper feeding system related service call The LCF transport motor is not rotating normally (when paper can be fed from any drawer except the LCF).
  • Remedy: 1 Is the LCF transport motor working? (Perform the output check: FS-03-122/ 172) Yes 2 No • Check if the connector CN3, CN30 of the LCF transport motor is disconnected. • Check if the signal line connector CN100 on the LCF board is disconnected. • Check if the power line connector CN101 on the LCF board is disconnected. • Check if the connector CN459, J700 on the PFC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF transport motor board, LCF board and PFC board are short circuited or open circuited.
    2 LCF transport motor PFC board • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF transport motor board, LCF board and PFC board are short circuited or open circuited. • Check if the PLL lock signal CN102 - 3 pin output from the LCF board is always “L” level. • Check if the voltage supplied to the microcomputer input terminal IC103 - 17 pin is always “L” level.
  • Code: C260
  • Description: Peak detection error
  • Causes: Scanning system related service call. Lighting of the exposure lamp (white reference) is not detected when power is turned ON.
  • Remedy: 1 Does the exposure lamp light? (Perform the output check: FS-03-267) Yes It is lit. 2 No It is not lit. 3
    2 Shading correction plate Check if there is any scratch or stain on the shading correction plate.
    Mirror Check if the mirror is tilted. 1. Check that the lens is reflected in the mirror looking at carriage-1 from the upper position. 2. Check that the mirror is secured at the leaf spring.
    Carriage 1. Check if the carriage is tilted by moving it to the left stopping point. 2. Check if the wire fixing screw is loosened. 3. Check if the movement of the carriage is unstable due to disengagement of the carriage roller.
    Exposure lamp 1. Check if the exposure lamp is correctly lit. 2. Check if the harness is connected properly to the exposure lamp connector. (CN123, CN010) 3. When the carriage is driven, check if the harness interferes with it or parts are caught in it.
    CCD board / Lens unit 1. Check if the connector of the CCD board is connected properly. (CN120, CN001) 2. Check if the CCD board is installed properly. (Check that the lens unit is not tilted or the screw is securely tighten.)
    SYS board 1. Check if the connector of the SYS board (CN120, CN123) is connected properly. 2. Check if the mounted parts on the SYS board are damaged or abnormal. 3. Check if the power is output from the SYS board for CCD. (CN122).
    3
    SYS board 1. Check if the supply cable is connected properly to the connector (CN105). 2. Check if the mounted parts on the SYS board are damaged or abnormal.
    Exposure lamp 1. Check if the harness of the exposure lamp is connected to the LED light source properly. (CN123, CN010) 2. Check if the exposure lamp is scratched or damaged. 3. Check if the exposure lamp harness comes off the board.
    Power supply harness 1. Check if wiring of the power supply harness (CN105) is abnormal. 2. Check if the harness is scratched or open circuited.
  • Code: C262
  • Description: Communication error
  • Causes: Scanning system related service call. Communication error between the CCD board and the SYS board. CPU abnormality.
  • Remedy: 1 Lens unit 1. Check if the connector is properly connected all the way in the CCD board. (CN001) 2. Check if there is any abnormality in the appearance of parts mounted on the CCD board. 3. Check if +5V is output to the CCD board. 4. Check if +3.3V is output from the CCD board. 5. Replace the Lens unit.
    2 SYS board 1. Check if the connector is properly connected all the way in the SYS board. (CN120) 2. Check if there is any abnormality in the appearance of parts mounted on the SYS board. 3. Check if +5V is output to the SYS board. 4. Replace the SYS board.
    3 Harnesses 1. Check if the harness has any scratch on it or is open circuited or caught anywhere. 2. Check if there is any abnormality in the connector terminal. 3. Replace the harness between the SYS board and the CCD board.
    4 RADF/DSDF 1. Turn the power OFF, disconnect the communication cable of the RADF/DSDF from the equipment and turn the power ON again. Then check if the error is reproduced. 2. If the error is reproduced, check if there is any abnormality in the communication cable and the connector between the RADF/DSDF and the equipment. 3. Replace the communication cable between the RADF/DSDF and the equipment. 4. Replace the RADF/DSDF.
  • Code: C270
  • Description: Carriage home position sensor not turning OFF within a specified period of time / Downloading firmware with an incorrect model
  • Causes: Scanning system related service call. Carriage home position sensor not turning OFF within a specified period of time/Downloading firmware with an incorrect model
  • Remedy: 1 Carriage locking Check if the carriage locking screw for packaging is attached.
    2 Are the carriages slightly moved to the feeding direction?/Are the carriages staying at a position other than home position? Yes Check if the circuits of the CCD board are abnormal. No 3
    3 CCD board • Check if the connector pin is disconnected or the harness is short circuited or open circuited. (CN001) • Check if the conductor pattern on the CCD board is short circuited or open circuited. • If the model of the firmware downloaded is incorrect, a C270 error (exposure lamp blinks twice) occurs. If the exposure lamp blinks twice, download the correct firmware.
    4 Carriage home position sensor 1. Check if the harness of the carriage home position sensor is connected properly. (CN121, J002) 2. Check if the harness is caught or open circuited.
    5 SYS board 1. Check if the connector of the SYS board (CN120, CN121, CN124, CN105) is connected properly. 2. Check if the mounted parts on the SYS board are damaged or abnormal. 3. Check if 24 V (CN105) on the SYS board is short circuited. 4. Check if 24 V is supplied to the SYS board (CN105).
    6 Scan motor 1. Check if the belt tension is loosened. 2. Check if the motor fixing screw is loosened. 3. Check if the carriage wire and the timing belt come off. 4. Check if the connector (CN124) is connected to the motor properly. 5. Check if the harness of the motor is caught or open circuited.
    7 Setting Clear the SRAM data and initialize them.
  • Code: C280
  • Description: Carriage home position sensor not turning ON within a specified period of time
  • Causes: Scanning system related service call Carriage home position sensor not going ON within a specified time.
  • Remedy: 1 Carriage locking Check if the carriage locking screw for packaging is attached.
    2 Carriage hole position sensor 1. Check if the harness is properly connected to the sensor. 2. Check if the harness is caught or open circuited.
    3 SYS board 1. Check if the harness (CN121, J002) of the carriage home position sensor is connected properly. 2. Check if the mounted parts on the SYS board are damaged or abnormal. 3. Check if 24 V (CM105) on the SYS board is short circuited. 4. Check if 24 V is supplied to the SYS board (CN105).
    4 Scan motor 1. Check if the belt tension is loosened (if the motor screw is loosened). 2. Check if the carriage wire and the timing belt come off. 3. Check if the connector (CN124) is connected to the motor properly. 4. Check if the harness of the motor is caught or open circuited.
  • Code: C290
  • Description: Scanner fuse blowout
  • Causes: Scanning system related service call The scanning system does not operate due to a blowout of the fuse in the scanning system.
  • Remedy: Is 24V supplied to the SYS board?
    Yes Check the following because the signal for checking 24V on the SYS board is abnormal. 1. Check if the scanner CPU (IC26) is damaged or abnormal. 2. Check if the mounted parts on the SYS board are damaged or abnormal. 3. Check if 24V on the SYS board is short circuited. 4. Check if 24V is supplied to the SYS board (CN105).
    No 1. Check if the 24V supply harness is properly connected to the connector (CN105). 2. Check if 24V and SG on the SYS board are short circuited. 3. Check if the power supply is short circuited by pulling out the supply harness on the SYS board (CN105). 4. Check if the fuse on the LVPS (F203) is open circuited. 5. Check if there is no abnormality on the LVPS.
Error Code
Service Mode, Troubleshooting