  • Code: 0112
  • Description: It is not possible to communicate with the Cartridge IC driver.
  • Causes: Cartridge IC driver has a problem (not working). The communication wire of Cartridge IC driver cable has short circuited or cut-line.
  • Remedy: Ink Cartridge IC sensor replacement
  • Code: 0148
  • Description: There is a problem with the Thermistor on the Cyan Head.
  • Causes: There is a bad connection between Cyan Head and Print Carriage Board (CN18). There is a bad connection between Print Carriage Board (CN2) and Head Board (CN1). Cyan Head is broken.
  • Remedy: Check cable connection between Head and Print Carriage Board (CN18). Check cable connection between Print Carriage Board (CN2) and Head Board (CN1). Cyan Head replacement.
  • Code: 0210
  • Description: The UV Lamp is not connected / tuned on.
  • Causes: There is a bad connection between UV Lamp and Print Carriage Board. There is a bad connection between DC Junction Board and Signal junction Board. Print Carrtiage Board is broken. DC Junction Board is broken. Signal Junction Board is broken. The UV Lamp is broken.
  • Remedy: Check cable connection between UV Lamp and Print Carriage Board. Check cable connection between DC Junction Board and Signal Junction Board. Print Carriage Board replacement DC Junction Board replacement Signal Junction Board replacement UV Lamp replacement
  • Code: 0211
  • Description: The UV Lamp is broken / There is a problem with the UV Lamp. The Thermistor in the UV Lamp is extremely high.
  • Causes: There is a bad connection between UV Junction Board and Signal Junction Board. UV Junction Board is broken. Signal Junction Board is broken. The filter of the UV Lamp is clogged. The UV Lamp is broken. *When the bad connections happen at the same time, Service Call [0211] occurs as a high priority.
  • Remedy: Check cable connection between Print Carriage Board and Signal Junction Board. Print Carriage Board replacement Signal Junction Board replacement UV Lamp Filter replacement UV Lamp replacement
  • Code: 0230
  • Description: Feed Origin Sensor does not work corrrectly.
  • Causes: Feed Motor error Defect of Feed Motor Gear Defect of Feed Belt Defect of Feed Origin Sensor Cut-line or short-circuit of cable and Flexible cable
  • Remedy: Feed Motor Replacement Feed Motor Gear Replacement Feed Belt Replacement Feed Origin Sensor Replacement Cable and Flexible Cable Replacement
  • Code: 0231
  • Description: Table Height Origin Sensor does not work corrrectly.
  • Causes: Table Motor error Defect of Table Unit Defect of Table Height Origin Sensor Cut-line or short-circuit of cable and Flexible cable
  • Remedy: Table Unit Replacement Cable and Flexible Cable Replacement Grease Up Maintenance