PrintCopy.info service

Ricoh SPC361SFNw

Error Codes List page 22

  • Code: SC995-01
  • Description: CPM setting error 1
    Comparison of machine serial number (11 digits) and machine identification code.
    Details: • Machine serial number cannot be identified because of BICU replacement or malfunctioning. • Machine serial number cannot be identified because of NV-RAM replacement
  • Causes: Machine serial number (11 digits) or machine identification code does not match.
  • Remedy: • Enter the machine serial number using SP5-811, and then turn the power on/off.
    • Attach the NV-RAM that was installed previously.
  • Code: SC995-02
  • Description: CPM setting error 2
    Comparison of machine serial number (11 digits) and machine identification code.
    Details:
    Machine serial number cannot be identified because of NV-RAM replacement or
    malfunctioning.
  • Causes: Machine serial number (11 digits) or machine identification code does not match.
  • Remedy: • Attach the NV-RAM that was installed previously.
    • Download data on the NV-RAM using SP5-825 (NV-RAM Data Download).
  • Code: SC995-03
  • Description: CPM setting error 3
    Comparison of machine serial number (11 digits) and machine identification code.
    Details:
    Unable to recognize machine identification code because the controller was replaced
    incorrectly or is malfunctioning.
  • Causes: Machine serial number (11 digits) or machine identification code does not match.
  • Remedy: Replace it with the correct type of controller.
  • Code: SC995-04
  • Description: CPM setting error 4
    Comparison of machine serial number (11 digits) and machine identification code.
  • Causes: Machine serial number (11 digits) or machine identification code does not match.
  • Remedy: Return the parts to the original configuration, and then replace them according to the manual
  • Code: SC997-00
  • Description: Application function selection error
    The application selected by the operation panel key operated abnormally (No response, abnormal ending).
  • Causes: Software bug (mainly the application)
  • Remedy: • Check the optional RAM, DIMM, boards required by the application program.
    • Check if the combination of downloaded programs are correct.
  • Code: SC998-00
  • Description: Application start error
    • No application was registered to system within a specified time after the main power was turned on. (No application starts/All applications have been terminated abnormally) • Application started but cannot be drawn now for some reason.
  • Causes: • Software bug (mainly the application)
    • The optional RAM, DIMM, boards required by the application program. Are not installed correctly.
  • Remedy: • Turn the main power off/on.
    • Check the optional RAM, DIMM, boards
    • Check the combination of programs
    • Replace the controller board.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?