PrintCopy.info service

Ricoh MP161L

Error Codes List page 7

  • Code: 901
  • Description: Mechanical total counter error
    The polling module does not detect the mechanical total counter.
  • Causes: • Defective mechanical total counter
    • Defective BICU
    • Loose connection
  • Code: 903
  • Description: Engine total counter error
    The checksum of the total counter is not correct.
  • Causes: • Defective NVRAM on the BICU
  • Code: 928
  • Description: Memory error
    An error occurs during the memory check conducted when the main power switch is turned on or when the copier is recovering from the energy saver mode.
  • Causes: • Defective memory
    • Defective BICU
    • Loose connection between the BICU and the memory
  • Code: 929
  • Description: IMAC hardware error
    A memory control job is not completed within a certain period.
  • Causes: • Defective IMAC
    • Defective BICU
    • Loose connection
  • Code: 981
  • Description: NVRAM error
    An error occurs during engine NVRAM check.
  • Causes: • Defective NVRAM
    • Loose connection between the BICU and the NVRAM
    • Incorrect installation of the NVRAM
    • Defective BICU
  • Code: 982
  • Description: Localization error
    The localization information in the nonvolatile ROM and in the NVRAM is different (* SP5-807-001).
  • Causes: • Localization setting not specified (The main power switch is turned on for the first time after the NVRAM is replaced.)
    • Incorrect localization setting
    • Defective NVRAM