Description: Accounting battery error
An error occurs in the battery of the MF accounting device.
Causes: • Defective accounting device
Code: 692
Description: Printer board communication error
• BICU does not get a signal from the printer board for 1.5 seconds or more.
• BICU gets a break-signal after completing the communication with the printer board and does not get a signal from the printer board for 10 seconds or more.
Causes: • Defective communication between BICU and printer board
Code: 694
Description: Scanner board communication error
• BICU does not get a signal from the scanner board for 1.5 seconds or more.
• BICU gets a break-signal after completing the communication with the scanner board and does not get a signal from the scanner board for 10 seconds or more.
Causes: • Defective communication between BICU and scanner board
Code: 760
Description: ADF gate error 1
The ADF sends the FGATE signal before it is requested to scan originals.