Ricoh D225 MP9003SP

Error Codes List page 1

  • Code: SC101-01
  • Description: Exposure lamp error: Front side scan
    The peak detection level reading on the reference white plate is too low.
  • Causes: • Defective exposure lamp LED
    • SBU (LED driver) on lens block defective
    • BICU defective
    • Power source, signal harness loose, broken, defective
    • Condensation in scanner unit
    • Scanner mirror or lens out of position or dirty
    • Reference white plate out of position or dirty
  • Remedy: • Check harness connections of exposure lamp, SBU, BICU
    • Inspect scanner unit for moisture. If moisture detected, install scanner heater.
    • Remove exposure glass and inspect scanner mirror, lenses and clean.
    • Raise ADF and check condition of white plate. Clean and re-position.
    • Replace exposure lamp.
    • Replace lens block with new SBU
    • Replace BICU.
  • Code: SC101-02
  • Description: Exposure lamp error: Front side (LR) scan initialization
    One or more of the elements in the LEDs on either side failed to light.
  • Causes: • LED (both sides) defective
    • SBU (LED driver) on lens block defective
    • Power source, signal harness loose, broken, defective
  • Remedy: • Cycle the machine off/on
    • If that does not solve the problem, inspect the exposure lamp harnesses for loose, broken, defective connection.
    • Reset the harnesses.
    • Replace exposure lamp LED PCBs.
    • Replace lens block (SBU LED driver)
  • Code: SC101-05
  • Description: Exposure lamp error: Front side (L) scan initialization
    One or more of the elements of the left LED failed to light.
  • Causes: • Left LED defective
    • SBU (LED driver) on lens block defective
    • Power source, signal harness loose, broken, defective
  • Remedy: • Cycle the machine off/on
    • If that does not solve the problem, inspect the exposure lamp harnesses for loose, broken, defective connection.
    • Reset the harnesses.
    • Replace exposure lamp LED PCBs.
    • Replace lens block (SBU LED driver)
  • Code: SC101-06
  • Description: Exposure lamp error: Front side (R) scan initialization
    One or more of the elements of the right LED failed to light.
  • Causes: • Right LED defective
    • SBU (LED driver) defective
    • Power source, signal harness loose, broken, defective
  • Remedy: • Cycle the machine off/on
    • If that does not solve the problem, inspect the LED harnesses for loose, broken, defective connection.
    • Reset the harnesses.
    • Replace right LED PCB.
    • Replace lens block (SBU LED driver)
  • Code: SC102-00
  • Description: Exposure lamp error: Front side
    The reading of the reference white plate within the specified number of pulses returned a value that was too high.
  • Causes: • LED defective
    • SBU (LED driver) defective
    • SBU defective
    • BICU defective
    • Power source harness, or signal harness loose, broken, defective
  • Remedy: • Cycle the machine off/on
    • Inspect and reset power harness, signal harness
    • Replace exposure LED PCBs
    • Replace lens block (SBU LED driver).
  • Code: SC120-00
  • Description: Scanner home position error 1
    The scanner HP sensor does not detect the OFF condition during initialization or copying.
  • Causes: • BICU defective
    • Scanner motor defective
    • Scanner HP sensor defective.
    • Harness between BICU, SIOB, scanner motor disconnected.
    • Harness between scanner HP sensor and BICU disconnected.
    • Scanner wire, timing belt, pulley, or carriage installed incorrectly.
  • Remedy: • Inspect installation of scanner wire, timing belt, pulley, carriage.
    • Inspect the harness between scanner HP sensor and BICU.
    • Check function of scanner HP sensor (input/output check) and replace sensor if defective.
    • Check operation of scanner motor (input/output check) and replace motor if defective.
    • Replace BICU.