  • Code: SC121-00
  • Description: Scanner home position error 2
    The scanner HP sensor does not detect the ON condition during initialization or copying.
  • Causes: • BICU defective
    • Scanner motor defective
    • Scanner HP sensor defective
    • Harness between BICU, SIOB, scanner motor disconnected
    • Harness between scanner HP sensor and BICU disconnected
    • Scanner wire, timing belt, pulley or carriage installed incorrectly.
  • Remedy: • Inspect installation of scanner wire, timing belt, pulley, carriage.
    • Inspect the HP sensor harness
    • Inspect harnesses to BICU
    • Check function of scanner HP sensor (input/output check) and replace sensor if defective.
    • Check operation of scanner motor (input/output check) and replace motor if defective.
    • Replace BICU.
  • Code: SC141-00
  • Description: Black level detection error
    The black level cannot be adjusted within the target during auto gain control.
  • Causes: • Harness to BICU loose, broken, defective
    • Defective SBU
    • Defective BICU
  • Remedy: • Check the harness connections from scanner unit to BICU
    • Replace the lens block (new SBU)
    • Replace the BICU
  • Code: SC142-00
  • Description: White level detection error
    The white level cannot be adjusted to the second target level within the target during auto gain control.
  • Causes: • Dirty exposure lamp or optics section
    • SBU board defective
    • BICU board defective
    • Harnesses are disconnected.
    • Exposure LED (lamp) defective
    • Lamp stabilizer defective
    • Scanner motor defective
  • Remedy: • Clean the exposure glass, white plate, mirrors, and lens.
    • Check if the exposure LEDs light during initialization
    • Check the harness connections
    • Replace the exposure LED lamps.
    • Replace the scanner motor.
    • Replace the lens block (SBU), BICU
  • Code: SC144-00
  • Description: SBU transmission error
    After the SBU switches on, the BICU detects one of the following conditions on the SBU: • 1 s after power on, the SYDO signal does not go high, even after 1 retry. • 1 s after power on, the SYDO signal goes high, but the SBU ID could not be read after 3 attempts.
  • Causes: • SBU defective
    • BICU defective
  • Remedy: • Inspect harness between scanner unit and BICU
    • Replace lens block (new SBU)
    • Replace BICU.
  • Code: SC151-00
  • Description: Black level error: Back side
    Not even one pixel was within permitted range when the black level was created.
  • Causes: • CIS defective
    • Replace CIS
  • Remedy: • Inspect CIS harnesses and connections.
    • Check CIS background roller for damage, clean dirt, check installation
    • Replace CIS.
  • Code: SC152-00
  • Description: White level error: Back side
    The value of the shading peak data return from the CIS device was defective.
  • Causes: • ADF CIS device defective
    • CIS white roller background or white plate damaged
    • CIS dirty or installed incorrectly
  • Remedy: • Inspect CIS harnesses and connections.
    • Check CIS background roller for damage, clean dirt, check installation
    • Replace CIS.