PrintCopy.info service

Ricoh Aficio 470W

Error Codes List page 1

  • Code: SC192
  • Description: AMDP download error
    The AMDP ROM enable signal could not be detected within 8 ms after program download to the AMDP started. Program download failed three times consecutively.
  • Causes: • AMDP program defective. • IC card defective • IPU defective
  • Code: SC302
  • Description: Charge Corona Output Error
    Charge corona feedback voltage of less than 1V was detected for more than 200 s.
  • Causes: • Charge power pack is defective. • High voltage cable is defective. • Poor connection of the power pack connector. • Dirty charge corona unit caused leakage.
  • Code: SC303
  • Description: Charge corona wire cleaner error
    1) Wire cleaner motor feedback voltage of less than 0.1 V was detected for more than 1s. 2) Corona wire cleaning did not complete within 80 s. 3) Charge wire cleaner did not return to the home position. 4) Cleaner does not move from the home position.
  • Causes: Wire cleaner motor connector disconnected. Wire cleaner motor connector disconnected. Wire cleaner motor is operating without a load. Wire cleaner stops due to an overload. Wire cleaner motor drive circuit malfunction.
  • Code: SC306
  • Description: Charge grid output error
    Control PWM duty value is higher than 1% (FB less than 1V) for more than 200 ms (a grid current leak).
  • Causes: • CBG power pack is defective. • High voltage cable is defective. • Poor connection of the power pack connector. • Dirty charge corona unit causing leakage
  • Code: SC330
  • Description: Writing ASIC signal error
    At power on, the stamp function could not execute successfully twice.
  • Causes: • SP5137 setting incorrect • Stamp board defective • Poor stamp board connection
  • Code: SC353
  • Description: ID sensor malfunction
    SC353-1 Vsp is 0V or more than 2.5 V SC353-2 Vsg is 0V or more than 2.5 V SC353-3 Edge pattern voltage (2.5 V) cannot be detected SC353-4 LED drive current (PWM value) is over 1000 or fixed at 0. SC353-5 Vsg cannot be adjusted to 4 ±0.2V within 20 s.
  • Causes: • ID sensor defective • ID sensor connector defective • IOB malfunction • CBG power pack defective • Dirty ID sensor • VDB defective • LPH defective