PrintCopy.info service

Mimaki CG60EX

Error Codes List page 3

  • Code: ERR26
  • Display: ERR26 I/F TEST n
  • Description: Signal cable fault.
  • Remedy: l. Connect a loop-back connector. 2. Replace the main PCB with a new one. n= I RS - CD loop fault n=2 ER - CS, DR loop fault n=3 TX time-out n=4 Conveyor error n=5 -8251 detection error
  • Code: ERR27
  • Display: ERR27 BUFFER over
  • Description: The size of the transmitted data is larger than the capacity of the receiver buffer.
  • Remedy: I. Check the interface conditions. 2. Check that the correct I/F cable is used for hardware handshaking. 3. Replace the main PCB assembly.
  • Code: ERR30
  • Display: ERR30 OPERATION
  • Description: Erromeous operation has been performed. (The dump function has been used while the dumping is being executed, or the copy function has been used while the copying is being executed.)
  • Remedy: 1. Check whether or not the performed operation is correct. 2. If the performed operation is correct, replace the keyboard assembly or the main PCB assembly.
  • Code: ERR31
  • Display: ERR31 NO DATA
  • Description: The receiver buffer stores no data, even though the "No. COPIES" or "COPY" operation is executed.
  • Remedy: Explain to the user that the "No. COPIES" function is valid only when the receiver buffer stores data.
  • Code: ERR32
  • Display: ERR32 DATA too BIG
  • Description: The "No. COPIES" and "COPY" operation has been executed after receiving the data, the size of which was larger than the capacity of the receiver buffer.
  • Remedy: Explain to the user that the data, the size of which is larger than the capacity of the receiver buffer, cannot be copied.
  • Code: ERR33
  • Display: ERR33 SHEET SIZE
  • Description: The length in the sheet feed direction (the X direction) is too short.
  • Remedy: Replace the sheet with a longer one (150mm or more).