Description: A device command, which could not be analyzed, has been received.
Remedy: I. Check the interface conditions. 2. Check whether or not the device command is correct by plotting received ASCII raw data, using the "Dump" function. 3. Analyze the command using a data monitor.
Code: ERR13
Display: ERR13 PM OVER
Description: The l 8Kbyte polygon buffer overflowed.
Remedy: Decompose the polygon data and transmit the data. Refer to the command manual.
Code: ERR15
Display: ERR15 AUTO FEED
Description: The sheet could not be fed the distance corresponding to the cutting data before cutting was performed.
Remedy: 1. Reset the sheet. 2. Set a sheet of sufficient length.
Code: ERR16
Display: ERR16 AUTO I/F
Description: Faulty command or interface conditions in "AUTO" setting of "COMMAND" function.
Remedy: Select "MGL-Ic l" or "MGL-Ilc" with "COMMAND" function and check the interface condition.
Code: ERR20
Display: ERR20 I/O
Description: Faulty interface conditions.
Remedy: Check the interface conditions.
Code: ERR25
Display: ERR25 BUFFER dump
Description: Interface between the unit and the host computer cannot be achieved when sending buffer dump via RS-232C.
Remedy: Check up the RS cable or the receiving procedure of host computer.