Description: Invalid operation has been taken during a temporary stop in the execution of cutting.
Remedy: Complete the cutting of remaining data or clear the data and re-execute cutting.
Code: ERR36
Display: ERR36 MARK detect
Description: 1. Operating procedure is not proper. (The pen tip does not fall within the "MARKdetect" at the start of detection.) 2. The sheet is placed with raised.
Remedy: I. Check up the operating procedure. 2. Check whether the sheet clamp is lowered and the sheet surface does not rise.
Code: ERR40
Display: ERR40 MOTOR A
Description: (Sheet feeding direction) Excessively increased load to the X servo motor.
Remedy: 1. Replace the X-axis motor assembly. 2. Replace the main PCB assembly. 3. Replace the power supply PCB assembly.
Code: ERR41
Display: ERR41 MOTOR B
Description: (widthwise direction) Excessively increased load to the Y servo motor.
Remedy: I. Replace the Y-axis motor assembly. 2. Replace the main PCB assembly. 3. Replace the power supply PCB assembly
Code: ERR42
Display: ERR42 A CURRENT
Description: An excess current error has been detected in servo motor X (the average current exceeded the motor's rating).
Remedy: 1. Adjust the X-axis belt tension. 2. Replace the main PCB assembly. 3. Replace servo motor X.
Code: ERR43
Display: ERR43 B CURRENT
Description: An excess current error has been detected in servo motor Y (the average current exceeded the motor's rating).
Remedy: I. Adjust the Y-axis belt tension. 2. Replace the main PCB assembly. 3. Replace servo motor Y.