Description: Abnormality detecting in FAX application
Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
Remedy: (1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a Controller board and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: FDEX
Description: Abnormality detecting in maintenance application
Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
Remedy: (1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a Controller board and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: FF7X
Description: Abnormality detecting in a report creation part
Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition. [Controller problem] Resolution is only power off / On.
Remedy: (1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a Controller board and perform an operation check. (3) Get USBLOG and contact service headquarters.