PrintCopy.info service

Kyocera ECOSYS M3645idn

Error Codes List page 1

  • Code: 0100
  • Description: Backup memory device error
  • Causes: EEPROM (Control PWB)
  • Remedy: 1. Turn the main power swtch off and after 5 seconds, then turn power on.
    2. Check that the EEPROM on the main circuit PWB is peroperly installed on the main circuit PWB and, if not, re-install it.
    3. Replace the control PWB and check for correct operation.
  • Code: 0120
  • Description: MAC address data error For data in which the MAC address is invalid.
  • Causes: EEPROM (Control PWB)
  • Remedy: 1 Turn the main power switch off and after 5 seconds, then turn power on.
    2 Check the MAC address on the network status page.
    3 If it is blank, obtain an EEPROM with its MAC address written from the service support and install.
    4 Replace the control PWB and check for correct operation.
  • Code: 0130
  • Description: Backup memory read/write error (main NAMD)
  • Causes: Flash memory (Control PWB)
  • Remedy: 1 Turn the main power switch off and after 5 seconds, then turn power on.
    2 Replace the control PWB and check for correct operation.
  • Code: 0140
  • Description: Backup memory data error (main NAND)
  • Causes: Flash memory (Control PWB)
  • Remedy: 1 Turn the main power switch off and after 5 seconds, then turn power on.
    2 Replace the control PWB and check for correct operation.
  • Code: 0150
  • Description: Backup memory read/write error (control PWB)
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from 2 locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Causes: EEPROM (Control PWB)
  • Remedy: 1 Turn the main power switch off and after 5 seconds, then turn power on.
    2 Check that the EEPROM is peroperly installed on the control PWB and re-install it.
    3 Replace the control PWB and check for correct operation.
    4 Check the EEPROM and if the data are currupted, contact the service support.
  • Code: 0160
  • Description: Backup memory data error (control PWB)
    Reading data from EEPROM is abnormal.
  • Causes: EEPROM
  • Remedy: 1 Turn the main power swtch off and after 5 seconds, then turn power on.
    2 Execute U021 - memory initializing.
    3 If the EEPROM data are currupted, contact the service support.