PrintCopy.info service

HP Color LaserJet CP5520 Series

Error Codes List page 15

  • Code: 59.00.F0
  • Display: 59.00.YY Error
  • Description: Printing error
    T1 alienation mechanism failure
  • Remedy: 1. Make sure that the ITB is correctly installed. 2. Use the T1 roller alienation switch (SW5) test in the Manual sensor test to verify that the switch is properly functioning. If it is not, replace the main drive assembly. 3. Use the T1 roller engagement and disengagement drive test in the component test to verify that the T1 roller disengagement mechanism is properly functioning. If it is not, replace the fuser drive assembly. 4. If the product has been serviced, check the connector (J181) on the DC controller PCA.
  • Code: 59.05.50
  • Display: 59.0X.50 Error
  • Description: Motor startup error
    Black image drum start up error (ITB motor; M1)
  • Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
  • Code: 59.05.70
  • Display: 59.0X.70 Error
  • Description: Motor abnormal rotation
    Black developer motor abnormal start up error (ITB motor; M1)
  • Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
  • Code: 59.05.80
  • Display: 59.0X.80 Error
  • Description: Developer motor failure
    Black developer motor failure error (ITB motor; M1)
  • Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
  • Code: 59.06.50
  • Display: 59.0X.50 Error
  • Description: Motor startup error
    CMY drum motor (M2) start up error
  • Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
  • Code: 59.06.60
  • Display: 59.0X.60 Error
  • Description: Motor rotational error
    CMY drum motor (M2) rotation error
  • Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.