Remedy: 1. Make sure that the ITB is correctly installed. 2. Use the T1 roller alienation switch (SW5) test in the Manual sensor test to verify that the switch is properly functioning. If it is not, replace the main drive assembly. 3. Use the T1 roller engagement and disengagement drive test in the component test to verify that the T1 roller disengagement mechanism is properly functioning. If it is not, replace the fuser drive assembly. 4. If the product has been serviced, check the connector (J181) on the DC controller PCA.
Code: 59.05.50
Display: 59.0X.50 Error
Description: Motor startup error
Black image drum start up error (ITB motor; M1)
Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
Code: 59.05.70
Display: 59.0X.70 Error
Description: Motor abnormal rotation
Black developer motor abnormal start up error (ITB motor; M1)
Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
Code: 59.05.80
Display: 59.0X.80 Error
Description: Developer motor failure
Black developer motor failure error (ITB motor; M1)
Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
Code: 59.06.50
Display: 59.0X.50 Error
Description: Motor startup error
CMY drum motor (M2) start up error
Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Code: 59.06.60
Display: 59.0X.60 Error
Description: Motor rotational error
CMY drum motor (M2) rotation error
Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.