PrintCopy.info service

Canon CLC5151

Error Codes List page 3

  • Code: E002-0006
  • Description: Insufficient temperature rise of fixing unit
    When the fixing main thermistor fails to reach 170 deg C within the prescribed period of time after reaching 150 deg C during warm-up
  • Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.
  • Code: E002-0101
  • Description: Insufficient temperature rise of fixing unit
    When the pressure main thermistor fails to reach 80 deg C within the prescribed period of time after reaching 50 deg C during warm-up
  • Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.
  • Code: E002-0102
  • Description: Insufficient temperature rise of fixing unit
    When the pressure main thermistor fails to reach 100 deg C within the prescribed period of time after reaching 80 deg C during warm-up
  • Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.
  • Code: E003-0001
  • Description: Fixing unit low temperature trouble
    When the fixing main thermistor has detected a temperature below 130 deg C for the prescribed period of time after standby
  • Remedy: Checking Disconnection of the Connector in the Thermistor Wiring. Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR
  • Code: E003-0002
  • Description: Fixing unit low temperature trouble
    When the pressure main thermistor has detected a temperature below 50 deg C for the prescribed period of time after standby
  • Remedy: Checking Disconnection of the Connector in the Thermistor Wiring. Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR
  • Code: E004-0101
  • Description: Fixing unit protection circuit trouble
    When there is a short-circuit detection error in the halogen heater (ASIC detection)
  • Remedy: Check the connection of the J114 jack of the AC driver PCB, and replace the AC driver PCB (triac short). Replace the Pressure heater. Replace the Fixing unit. Replace the DC controller PCB 2 (MAISY).