Description: Fixing unit protection circuit trouble
When the difference in temperature between the front and back of the fixing belt is higher than the rating
Remedy: Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).
Code: E004-0201
Description: Fixing unit protection circuit trouble
When the difference in temperature between the front and back of the fixing belt is higher than the rating
Remedy: Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).
Code: E004-0202
Description: Fixing unit protection circuit trouble
When the difference in temperature between the center and front of the fixing belt is higher than the rating
Remedy: Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).
Code: E004-0203
Description: Fixing unit protection circuit trouble
When the difference in temperature between the center and back of the fixing belt is higher than the rating
Remedy: Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).
Code: E004-0204
Description: Fixing unit protection circuit trouble
When the difference in temperature between the front and back of the pressure belt is higher than the rating
Remedy: Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).
Code: E004-0205
Description: Fixing unit protection circuit trouble
Thermistor temperature difference error (combination unknown)
Remedy: Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).