  • Code: E001-0102
  • Description: Abnormally high temperature rise of fixing unit (circuit trouble)
    When pressure sub-thermistor 1 has detected a high temperature (ASIC detection)
  • Remedy: Check the connection of the connector in the thermistor wiring (wirepinching, disconnection). Replace the fixing unit. Replace the IH unit, halogen heater, fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.
  • Code: E001-0103
  • Description: Abnormally high temperature rise of fixing unit (circuit trouble)
    When pressure sub-thermistor 2 has detected a high temperature (ASIC detection)
  • Remedy: Check the connection of the connector in the thermistor wiring (wirepinching, disconnection). Replace the fixing unit. Replace the IH unit, halogen heater, fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.
  • Code: E002-0002
  • Description: Insufficient temperature rise of fixing unit
    When the fixing main thermistor fails to reach 80 deg C within the prescribed period of time after reaching 50 deg C during warm-up
  • Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.
  • Code: E002-0003
  • Description: Insufficient temperature rise of fixing unit
    When the fixing main thermistor fails to reach 110 deg C within the prescribed period of time after reaching 80 deg C during warm-up
  • Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.
  • Code: E002-0004
  • Description: Insufficient temperature rise of fixing unit
    When the fixing main thermistor fails to reach 130 deg C within the prescribed period of time after reaching 110 deg C during warm-up
  • Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.
  • Code: E002-0005
  • Description: Insufficient temperature rise of fixing unit
    When the fixing main thermistor fails to reach 150 deg C within the prescribed period of time after reaching 130 deg C during warm-up
  • Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.