Error Codes List page 1
|
|
- Code: 0002
- Description: Disorder of communication with Sub CPU. This occurs when the Sub CPU is not detected after turning on the machine.
- Causes: Sub Board does not work correctly. Sub CPU does not work correctly. A bad connection between Main Board and Servo Board.
- Remedy: Check cable connection of Main Board - Servo Board. Servo Board replacement Main Board replacement
- Code: 0101
- Description: Limit Position Initialize has not been done.
- Causes: Limit Position Initialize has not been done correctly.
- Remedy: Carry out Limit Position Initialize.
- Code: 0102
- Description: Even though the machine takes a normal action, the output of Limit Sensor does not reach the desired value.
- Causes: Limit Sensor does not work correctly or is broken.
- Remedy: Limit Sensor replacement Check the backlash or loose with the driving parts of the carriage.
- Code: 0104
- Description: Even though the machine takes a regular action, the output of Capping Sensor does not reach the desired value.
- Causes: Capping Motor disorder Capping Unit does not work correctly Capping Sensor disorder Wiring or card cable has short-circuit or cut-line
- Remedy: Check cable connection of Servo Board Check cable connection of Junction Board Capping Motor replacement Capping unit replacement Capping Sensor replacement Flexible Cable replacement
- Code: 0107
- Description: Linear Encoder Setup has not been done.
- Causes: Linear Encoder Setup has not been done correctly
- Remedy: Carry out Linear Encoder Setup in service menu
- Code: 0108
- Description: Even though the machine takes normal action, the output of the Wiper Height Sensor does not reach the desired value.
- Causes: Disorder of Wiper Height Sensor Fault of Wiper Unit Fault of Wiper Height Sensor Cut-line or short-circuit of cable and card cable
- Remedy: Wiper Height Motor Replacement Wiper Unit Replacement Wiper Height Sensor Replacement Cable and Flexible Cable Replacement