PrintCopy.info service

Ricoh SP8400DN

Error Codes List page 1

  • Code: SC202-00
  • Description: Polygon Motor: ON Timeout Error
    After the polygon motor turned on, or within 10 sec. after the rpm’s changed, the motor did not enter READY status.
  • Causes: • The interface harness to the polygon motor driver damaged or not connected correctly.
    • Polygon motor or polygon motor driver defective
    • Polygon motor drive pulse cannot be output correctly. (Polygon controller)
    • XSCRDY signal observation failing (Polygon controller)
  • Remedy: • Turn the power off/on.
    • Replace the laser unit.
    • Replace the harness.
    • Replace the IPU board.
  • Code: SC203-00
  • Description: Polygon Motor: OFF Timeout Error
    The XSCRDY signal (polygon ready) never becomes inactive (H) within 3 sec. after the polygon motor went OFF.
  • Causes: • The interface harness to the polygon motor driver damaged or not connected correctly.
    • Polygon motor or polygon motor driver defective
    • Polygon motor drive pulse cannot be output correctly. (Polygon controller)
    • XSCRDY signal observation failing (Polygon controller)
  • Remedy: • Turn the power off/on.
    • Replace the laser unit.
    • Replace the harness.
    • Replace the IPU board.
  • Code: SC204-00
  • Description: Polygon Motor: XSCRDY Signal Error
    During polygon motor rotation, the XSCRDY signal was inactive (H) for longer than one rotation of the polygon.
  • Causes: • The interface harness to the polygon motor driver damaged or not connected correctly.
    • Polygon motor or polygon motor driver defective
  • Remedy: • Turn the power off/on.
    • Replace the laser unit.
    • Replace the harness.
    • Replace the IPU board.
  • Code: SC220-00
  • Description: Laser Synchronization Detection Error: Leading Edge
    The laser synchronizing detection signal for the start position of the LD was not output for 200msec. after LDB unit turned on with the polygon motor rotating normally.
  • Causes: • The interface harness to the synchronization detection unit damaged or not connected correctly.
    • Synchronization detection board defective
    • Beam does not enter photo detector.
    • Abnormality around GAVD
    • IDB (LED driver) defective
    • LDB defective
    • IPU defective
  • Remedy: • Turn the power off/on.
    • Replace the laser unit.
    • Replace the harness.
    • Replace the IPU board.
  • Code: SC230-00
  • Description: FGATE ON Error
    The FGATE signal did not turn ON within the given time period after the writing process started.
  • Causes: • GAVD defective
    • Image processing ASIC defective
    • BCU, controller board not connected correctly or defective
    • Harness between BCU and LDB defective
  • Remedy: • Turn the power off/on.
    • Replace the harness between IPU and laser unit.
    • Replace the IPU board.
    • Replace the controller board.
  • Code: SC231-00
  • Description: FGATE OFF Error
    The FGATE signal did not turn OFF within the given time period after the writing process ended.
  • Causes: • GAVD defective
    • Image processing ASIC defective
    • IPU, controller board not connected correctly or defective
    • Harness between IPU and LDB defective
  • Remedy: • Turn the power off/on.
    • Replace the harness between IPU and laser unit.
    • Replace the IPU board.
    • Replace the controller board.