Description: LD Error • The LD error status of LD driver is asserted after the LD is initialized. • The LD driver's error signal is detected during LD initialization.
Causes: • LD degradation (LD broken, shift of output characteristics etc.) • The interface harness damaged or not connected correctly. • LD driver defective
Remedy: • Cycle the main power off/on. • Replace the laser unit. • Replace the harness. • Replace the IPU board.
Code: SC272-01
Description: LD Driver Communication Error If the value is not same when the machine reads and writes the same registration at the machine start-up. If the communication parity retries three consecutive times, the SC is generated.
Remedy: • Cycle the main power off/on. • Replace the laser unit. • Replace the harness. • Replace the IPU board.
Code: SC302-00
Description: High Voltage Power Source: Charge: Output Error The machine detects the error detection signal “L (unexpected)” 10 times for 200 msec consecutively when monitoring the error signal every 20 msec during outputting the PWM signal.
Causes: Hardware error • Input / Output connector is disconnected. • Input / Output harness is short-circuited. • Surface/air clearance insufficient (arc discharge) • BCU error (signal error) • HVPS defective Load error • Grounding fault of charging output, short-circuit with other outputs • Surface/air clearance insufficient in charging output path (including distance from other outputs) • Unexpected deterioration of drum and over current due to pinholes gap error between the drum and charge roller (PCU error). • Over current due to drum surface condensation • PCU is disconnected.
Remedy: • Cycle the main power off/on. • Replace the HVPS. • Replace the harness of the HVPS. • Replace the harness of the PCU. • Replace the PCU.
Code: SC324-01
Description: Development Motor: Bk: Lock Lock signals are observed at 2 sec intervals during motor ON, and a High level is detected at least 20 times.
Causes: • Motor defective • Connector disconnected • Harness broken • BCU defective • Unit torque increased
Remedy: • Replace the development motor. • Reconnect the connector. • Replace the harness. • Replace the BCU. • Replace the development unit. • Replace the driven unit.
Code: SC360-01
Description: TD Sensor Adjustment Error • When Mu count exceeds the judgment threshold of no developer status. • When Mu count does not satisfy the following target ranges for 3 times in a row. • Upper threshold • Lower threshold
Causes: • TD sensor defective • Loose connection • Harness broken • Developer toner density differs from initial developer
Remedy: • Replace the TD sensor harness. • Reconnect the TD sensor connector. • Replace the TD sensor. • Replace the development unit.