PrintCopy.info service

Ricoh M282 SP5310DN

Error Codes List page 1

  • Code: SC101-01
  • Description: Lamp Error (Scanning)
    The white level peak did not reach the prescribed threshold when the white guide plate was scanned. Error detection timing;
    • During a scan from the exposure glass: When the scanning of white guide plate is completed. (when the SHGH is negated)
    • During a scan from ARDF: During the shading operation. When the scanning of white guide plate is completed. (when the SHGH is negated)
  • Causes: • Condensation in scanner unit
    • Connector disconnected
    • Scanner Carriage defective
    • BiCU defective
    • Harness defective
    • White Guide Plate dirty or defective
    • IOB defective
  • Remedy: Check if the SC occurs by turning the main power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
    1. Reconnect the connector. Reconnect the following connectors; • Scanner Carriage – BiCU connector • BiCU – IOB connector 2. Check the white guide plate (exposure glass). Check the white guide plate attached to the exposure glass. If the white guide plate is in an unusual state, replace the white guide plate. 3. Scanner carriage defective Replace the scanner carriage. 4. BiCU defective Replace the BiCU. 5. Harness defective Replace the following harnesses. • Scanner Carriage – BiCU harness • BiCU – IOB harness 6. IOB defective Replace the IOB.
  • Code: SC101-02
  • Description: Lamp Error (Detecting the lighting error)
    The white level peak did not reach the prescribed threshold when the white guide plate was scanned. Error detection timing; During the scanner adjustment (detecting the lighting error) at the time of applying power source for scanner (when the main power is turned ON).
  • Causes: • Condensation in scanner unit
    • Connector disconnected
    • Scanner Carriage defective
    • BiCU defective
    • Harness defective
    • White Guide Plate dirty or attachment fault
    • IOB defective
  • Remedy: Check if the SC occurs by turning the main power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
    1. Reconnect the connector. Reconnect the following connectors; • Scanner Carriage – BiCU connector • SBU – LEDB connector (SBU side connector on the scanner carriage) • BiCU – IOB harness 2. Check the white guide plate (exposure glass). Check the white guide plate attached to the exposure glass. If the white guide plate is in an unusual state, replace the white guide plate. 3. Scanner carriage defective Replace the scanner carriage. 4. BiCU defective Replace the BiCU. 5. Harness defective Replace the following harnesses. • Scanner Carriage – BiCU harness • BiCU – IOB harness 6. IOB defective Replace the IOB.
  • Code: SC102-00
  • Description: LED Light Quantity Error
    The white level peak exceeded the prescribed threshold when the white guide plate was scanned. Error detection timing; During the scanner adjustment (detecting the lighting error) at the time of applying power source for scanner (when the main power is turned ON).
  • Causes: • Connector disconnected
    • Scanner Carriage defective
    • BiCU defective
    • Harness defective
    • IOB defective
  • Remedy: Check if the SC occurs by turning the main power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
    1. Reconnect the connector. Reconnect the following connectors; • Scanner Carriage – BiCU connector • SBU – LEDB connector (SBU side connector on the scanner carriage) • BiCU – IOB harness 2. Check the white guide plate (exposure glass). Check the white guide plate attached to the exposure glass. If the white guide plate is in an unusual state, replace the white guide plate. 3. Scanner carriage defective Replace the scanner carriage. 4. BiCU defective Replace the BiCU. 5. Harness defective Replace the following harnesses. • Scanner Carriage – BiCU harness • BiCU – IOB harness 6. IOB defective Replace the IOB.
  • Code: SC120-00
  • Description: Scanner Home Position error
    The home position is not correct when the main power is turned ON, at the end of a reading process from the exposure glass and ARDF.
  • Causes: • Scanner motor defective
    • Scanner HP sensor defective
    • SBU defective
    • BiCU defective
    • Controller board defective
  • Remedy: • Scanner motor defective 1. Move the scanner carriage by hand to check whether it is unusually difficult to move. 2. Check that the scanner driving belt is not disengaged. 3. Reconnect the following connector. Scanner Motor – Controller Board connector 4. If the connector is broken, shorted, or grounded, replace the connector. 5. Replace the scanner motor.
    • Scanner HP sensor defective 1. Check that the scanner HP sensor is correctly positioned. 2. Reconnect the following connectors. • Scanner HP Sensor – SBU connector • SBU – Controller Board connector 3. Replace the scanner HP sensor. • SBU defective Replace the scanner unit. • BiCU defective Replace the BiCU. • Controller board defective Replace the controller board.
  • Code: SC141-00
  • Description: Black level detection error
    The black level cannot be adjusted to the target level at the time of applying power source for scanner (when the main power is turned ON).
  • Causes: • Scanner Carriage defective
    • BiCU defective
    • Harness defective
    • IOB defective
  • Remedy: Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
    1. Reconnect the following connectors. • Scanner Carriage – BiCU connector • BiCU – IOB connector 2. Scanner carriage defective Replace the scanner carriage. 3. BiCU defective Replace the BiCU. 4. Harness defective Replace the following harnesses. • Scanner Carriage – BiCU harness • BiCU – IOB harness 5. IOB defective Replace the IOB.
  • Code: SC142-00
  • Description: White level detection error
    The white level cannot be adjusted to the target level during auto gain control.
  • Causes: • Condensation in scanner unit
    • Scanner Carriage defective
    • BiCU defective
    • Harness defective
    • Connector disconnected
    • White Guide Plate dirty or attachment fault
  • Remedy: Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
    1. Reconnect the following connectors. • Scanner Carriage – BiCU connector • SBU – LEDB connector (SBU side connector which is on the scanner carriage) • BiCU – IOB connector 2. Check the white guide plate (exposure glass). Check the white guide plate attached to the exposure glass. If the white guide plate is in an unusual state, replace the white guide plate. 3. Scanner carriage defective Replace the scanner carriage. 4. BiCU defective Replace the BiCU. 5. Harness defective Replace the following harnesses. • Scanner Carriage – BiCU harness • BiCU – IOB harness 6. IOB defective Replace the IOB.