Error Codes List page 1
|
|
- Code: E7-01
- Description: Duplex model memory setup error, memory not-detected error
- Causes: The memory is not set properly or the memory capacity is not set to the duplex setup (6M). Cancel method: Set SIM 26-39 code number to 2.
- Code: E7-03
- Description: HSYNC not detected.
- Causes: LSU (laser diode, reception element, APC circuit) trouble LSU drive circuit (ASIC) trouble
- Code: E7-04
- Description: CCD white level trouble
- Causes: CCD drive circuit (CCD PWB, ASIC harness) trouble Copy lamp lighting trouble (Copy lamp, invertor PWB)
- Code: E7-05
- Description: CCD black level trouble
- Causes: CCD drive circuit (CCD PWB, ASIC, harness) trouble
- Code: E7-12
- Description: Shading trouble (White correction)
- Causes: Dirt on white plate for scanning white level
- Code: E7-14
- Description: ASIC connection trouble
- Causes: Improper connection between CPU and ASIC (pattern cut, improper connection of lead pin)