  • Code: 0211
  • Description: The UV Lamp is broken / There is a problem with the UV Lamp.
    The Thermistor in the UV Lamp is extremely high.
  • Causes: There is a bad connection between Print Carriage Board and UV Junction Board.
    There is a bad connection between UV Junction Board and Step Drive Board.
    There is a bad connection between Step Drive Board and Servo Board.
    The filter of the UV Lamp is clogged. The UV Lamp is broken.
  • Remedy: Check the lighting of [DC OK] LED on the UV device while the IS Cover Sensor, Front Cover Sensor and Maintenance Cover Sensor is turned on. If it does not light, the UV device itself could be broken.
    Check cable connection between Print Carriage Board and UV Junction Board.
    Check cable connection between UV Junction Board and Step Drive Board.
    Check cable connection between Step Drive Board and Servo Board.
    Print Carriage Board replacement
    UV Junction Board replacement
    Step Drive Board replacement
    Servo Board replacement
    UV Lamp Filter replacement.
    UV Lamp replacement
  • Code: 0212
  • Description: The UV Lamp Unit and UV Lamp Sensor do not work correctly.
  • Causes: UV Lamp Motor error
    Defect of UV Lamp Sensor
    Defect of UV Lamp Unit
    There is a bad connection between UV Lamp Unit and Print Carriage Board.
    There is a bad connection between Print Carriage Board and UV Junction Board.
    There is a bad connection between UV Junction Board and Signal Junction Board.
  • Remedy: UV Lamp Motor replacement
    UV Lamp Sensor replacement
    UV Lamp Unit replacement
    Check cable connection between UV Lamp Unit and Print Carriage Board.
    Check cable connection between Print Carriage Board and UV Junction Board.
    Check cable connection between UV Junction Board and Signal Junction Board.