  • Code: 00010003
  • Display: SERVICE CALL 00010003: PF MOTOR IN POSITION TIME OUT
  • Description: When be it locateds stable at the time of halt processing with the PF motor control, (the in position time) the position control inside period did not improve.
  • Remedy: • PF motor exchange • PF encoder exchange • PF timing belt exchange • C362DRV board exchange
  • Code: 00010004
  • Display: SERVICE CALL 00010004: CR ENCODER CHECKING ERROR
  • Description: CR motor encoder check error The CR motor makes small revolutions clockwise and counter-clockwise.When it turns, the printer checks the encoder output signals to make sure the motor is turning at the correct speed/distance. If the encoder doesn’t send the correct signal or output data, an error occurs.
  • Remedy: It confirms whether there is not abnormal load etc. at the time of carriage migration and be abnormal no and do the checking of the CR encoder, in the case that the error is not canceled. In the case that there is abnormality : Carry out the tension of the steel belt adjustment or CR motor exchange. In the case that there is not abnormality : Confirm whether there are not dirt and damage in the CR encoder. The cable connector joint to the CR encoder and head Assy board CN15 are confirmed. Encoder pulse detection for T fence (scale 180a) of it comes off/whether or not there is not the contact with a CR encoder • Confirmation of the dirt/paper powder/damage of the confirmation T fence (scale 180a) the top • CR encoder exchange • CR motor exchange • C362DRV board exchange
  • Code: 00010005
  • Display: SERVICE CALL 00010005: CR MOTOR STEP-OUT
  • Description: The rotational speed of the CR motor abnormal. (it is long/short period at the time of prescription ).
  • Remedy: It confirms whether there is not abnormal load etc. at the time of carriage migration and be abnormal no and do the checking of the CR encoder, in the case that the error is not canceled. In the case that there is abnormality: • Encoder pulse detection for T fence (scale 180a) of it comes off/whether or not there is not the contact with a CR encoder • Tension adjustment of the confirmation steel belt • Confirmation of the dirt / paper powder / damage of the T fence (scale 180a) the top • CR encoder exchange • CR motor exchange • C362DRV board exchange
  • Code: 00010006
  • Display: SERVICE CALL 00010006: CR MOTOR OVER CURRENT
  • Description: CR motor overcurrent - Feedback from the CR motor (IC33) driver’s 10-pin output (Sense signal) indicates that the CR motor’s current is irregular.
  • Remedy: • He resistance value (5.56) the measurement of the n CR motor. In the case that the CR motor exchange motor coil is short condition if there is abnormality exchange.C362DRV board exchange even the C362DRV board • C362DRV board exchange
  • Code: 00010007
  • Display: SERVICE CALL 00010007: CR MOTOR IN POSITION TIME OUT
  • Description: When be it locateds stable at the time of halt processing with the CR motor control, (the in position time) the position control inside period did not improve.
  • Remedy: • Tension adjustment of the n steel belt • CR encoder exchange • CR motor exchange • C362DRV board exchange.
  • Code: 00010008
  • Display: SERVICE CALL 00010008: SERVO INTERRUPTION WATCH DOG TIME OUT ERROR
  • Description: System abnormal
  • Remedy: • C362DRV board exchange • C362MAIN board exchange
Error Code