PrintCopy.info service

Epson Stylus Pro 10600

Error Codes List page 2

  • Code: 00000101
  • Display: SERVICE CALL 00000101: CR motor life (Even Ink tube life)
  • Description: The carriage drive system reached the life.
  • Remedy: The following confirmation and also part exchange and CR motor initialization • Whether there is not ink leakage from the ink supply tube and also coupling department, is confirmed. • It confirms whether there are not dirt and abrasion in the slowing-down gear that was attached to the CR timing belt, PF roller axis. • The CR timing belt tension confirms whether or not it is normal. • Exchange the CR motor and ink tube. After the above part are exchanged, "CR motor Initialization" of maintenance mode 2 is run.
  • Code: 00000102
  • Display: SERVICE CALL 00000102 :Waste ink box on the right side full
  • Description: It is ’00,000,100’ and time in the detailed that displayed it to the LCD panel and be not fatal error.
  • Remedy: Not necessary ("Waste ink Initialization" of maintenance mode 2 is run.)
  • Code: 00000103
  • Display: SERVICE CALL 00000103 : Waste ink box on the left side full
  • Description: It is ’00,000,100’ and time in the detailed that displayed it to the LCD panel and be not fatal error.
  • Remedy: Not necessary ("Waste ink Initialization" of maintenance mode 2 is run.)
  • Code: 00010000
  • Display: SERVICE CALL 00010000: PF ENCODER CHECK ERROR
  • Description: PF motor encoder check error The PF motor makes small revolutions clockwise and counter-clockwise. When it turns, the printer checks the rotary encoder (inside the motor) output signals to make sure the motor is turning at the correct speed/distance. If the encoder sends an incorrect signal, an error occurs.
  • Remedy: Make sure there is nothing blocking the grid rollers. If that does not solve the problem, check the PF motor encoder connection. If there still is a problem, carry out the tension adjustment or phenol-formaldehyde motor exchange of the phenol-formaldehyde timing belt. If there is not a problem, carry out the following items. • Confirming whether the dirt and dust are not adhering to the PF loop scale and PF encoder. • The cable connector joint of the PF encoder and C362DRV board (CN8) are confirmed. • The PF timing belt tension confirmation/adjustment. In the case that there is not abnormality with above checking I gradually exchange the next part. • PF encoder • PF timing belt • PF loop scale • PF encoder extension cable • C362DRV board
  • Code: 00010001
  • Display: SERVICE CALL 00010001: PF MOTOR STEP-OUT
  • Description: PF motor out of step - the length of the PF motor internal encoder’s pulse is too long or too short compared to the regular pulse.
  • Remedy: Make sure there is nothing blocking the grid rollers. If that does not solve the problem, check the PF motor encoder connection. If there still is a problem, try the following. • PF timing belt exchange • PF motor exchange • PF motor extension cable exchange • C362DRV board exchange.
  • Code: 00010002
  • Display: SERVICE CALL 00010002: PF MOTOR OVER CURRENT
  • Description: PF motor overcurrent - Feedback from the PF motor (IC35) driver’s 10-pin output (sensor signal) indicates that the PF motor’s current is irregular.
  • Remedy: • The coil resistance value (6.7Ohm) the measurement of the PF motor. • PF motor extension cable exchange. • C362DRV board exchange.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us