Remedy: Compare the serial number of the equipment with a number displayed in 08-995. If they are different, enter the correct serial number at 08-995.
Code: F200
Description: Data overwrite option (GP-1070) disabled
Remedy: Perform firmware installation (some firmware: OS, HDD, SYS, Laser Firmware, PFC Firmware, Engine Main Firmware, and Scanner Firmware) with the USB media. "6.1 Firmware Updating with USB Media" * When the function of the Data Overwrite Enabler (GP-1070) is deleted from the equipment, the service call “F200” occurs.
Code: F350
Description: SLG board abnormality
Remedy: (1) Check if the conductor pattern on the SLG board is short circuited or open circuited. (2) If there is no problem found in the check (1) above, check the combination of the firmware version of the system ROM, engine ROM and scanner ROM. Reinstall the scanner ROM firmware. (3) If an error occurs after step (2) above has been performed, replace the SLG board.
Code: F400
Description: SYS board cooling fan abnormality
Remedy: (1) Check if the fan is rotating properly. (2) If not, check if any foreign object is adhered. (3) Are the connector CN112 and the relay connector of the SYS board connected securely? (4) Replace the SYS board cooling fan.