  • Code: C1B0
  • Description: LCF transport motor abnormality
  • Causes: Paper feeding system related service call The LCF transport motor is not rotating normally (when paper can be fed from any drawer except the LCF).
  • Remedy: 1 Is the LCF transport motor working? (Perform the output check: FS-03-122/172) Yes 2 No • Check if the connector CN3, CN30 of the LCF transport motor is disconnected. • Check if the signal line connector CN100 on the LCF board is disconnected. • Check if the power line connector CN101 on the LCF board is disconnected. • Check if the connector CN315 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF transport motor board, LCF board and LGC board are short circuited or open circuited.
    2 LCF transport motor • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF transport motor board, LCF board and LGC board are short circuited or open circuited. • Check if the PLL lock signal CN102 - 3 pin output from the LCF board is always “L” level. • Check if the voltage supplied to the microcomputer input terminal IC103 - 17 pin is always “L” level.
  • Code: C260
  • Description: Peak detection error
  • Causes: Scanning system related service call Peak detection error
  • Remedy: 1 Is the exposure lamp lit? (Output check: FS-03-267) Yes It is lit. 2 No It is not lit. 3
    2
    Shading correction plate • Check if there is any scratch or stain on the shading correction plate. • Check if the shading correction plate is any scratch or dirty.
    Mirror Check if the mirror is tilted. - Check that the lens is reflected in the mirror looking at carriage- 1 from an upper position. - Check that the mirror is secured at the leaf spring. Notes: Do not turn the mirror adjustment screw more than necessary.
    Carriage • Check if the carriage is tilted by moving it to the left stopping point. • Check if the wire fixing screw is loosened. • Check if the movement of the carriage is unstable due to disengagement of the carriage roller.
    Exposure lamp • Check if the exposure lamp is flickering when it is turned on. • Check if the connector is properly connected all the way in the board of LED lamp unit. • While the carriage is being driven, check if the harness catches it or interferes with it.
    CCD board • Check if the connector is properly connected all the way in the CCD board. • Check if the CCD board or the lens unit is tilted. Check if the screw is securely tightened. • Replace the lens unit.
    SYS board • Check if the connector is properly connected all the way in the SYS board. (CN120, CN123) • Check if there is any abnormality in the parts mounted on the SYS board or in the appearance of the SYS board. • Check if the voltage is output from the power supply for the CCD. • Replace the SYS board.
    3
    Exposure lamp • Check if the connector is properly connected to the board of LED lamp unit. • Check if there are any scratches or damage on the board of LED lamp unit. • Replace the exposure lamp unit.
    Harness • Check if wiring of the harness (CN125 on the SYS board) is abnormal. • Check if the harness (CN125 on the SYS board) has any scratch on it or is open circuited or caught anywhere. • Replace the harness (CN125 on the SYS board).
  • Code: C262
  • Description: Communication error
  • Causes: Scanning system related service call Communication error between the CCD board and the SYS board
  • Remedy: 1 Lens unit • Check if the connector is properly connected all the way in the CCD board. • Check if there is any abnormality in the appearance of parts mounted on the CCD board. • Check if +5V is output to the lens unit. • Check if the voltage is output from the CCD board. • Replace the Lens unit.
    2 SYS board • Check if the connector is properly connected all the way in the SYS board. (CN120) • Check if there is any abnormality in the appearance of parts mounted on the SYS board. • Check if +5V is output to the SYS board. • Replace the SYS board.
    3 Harnesses • Check if the harness has any scratch on it or is open circuited or caught anywhere. • Check if there is any abnormality in the connector terminal. • Replace the harness between the SYS board and the CCD board.
    4 RADF/DSDF • Turn the power OFF, disconnect the communication cable of the RADF/DSDF from the equipment and turn the power ON again. Then check if the error is reproduced. • If the error is reproduced, check if there is any abnormality in the communication cable and the connector between the RADF/DSDF and the equipment. • Replace the communication cable between the RADF/DSDF and the equipment. • Replace the RADF/DSDF.
  • Code: C270
  • Description: Carriage home position sensor not turning OFF within a specified period of time/ Downloading firmware with an incorrect model
  • Causes: Scanning system related service call Carriage home position sensor not turning OFF within a specified period of time/Downloading firmware with an incorrect model
  • Remedy: 1 Carriage locking Check if the carriage locking screw for packaging is attached.
    2 Are the carriages slightly moved to the feeding direction?/Are the carriages staying at a position other than home position? Yes Check if the circuits of the CCD board are abnormal. No 3
    3 CCD board • Check if the connector pin is disconnected or the harness is short circuited or open circuited. (CN001) • Check if the conductor pattern on the CCD board is short circuited or open circuited. • If the model of the firmware downloaded is incorrect, a C270 error (exposure lamp blinks twice) occurs. If the exposure lamp blinks twice, download the correct firmware.
    4 Carriage home position sensor • Check if the harness of the carriage home position sensor is connected properly. (CN121, J002) • Check if the harness is caught or open circuited.
    5 SYS board • Check if the connector of the SYS board (CN120, CN121, CN124, CN105) is connected properly. • Check if the mounted parts on the SYS board are damaged or abnormal. • Check if 24 V (CN105) on the SYS board is short circuited. • Check if 24 V is supplied to the SYS board (CN105).
    6 Scan motor • Check if the belt tension is loosened. • Check if the motor fixing screw is loosened. • Check if the carriage wire and the timing belt come off. • Check if the connector (CN124) is connected to the motor properly. • Check if the harness of the motor is caught or open circuited.
    7 Setting Clear the SRAM.
  • Code: C280
  • Description: Carriage home position sensor not turning ON within a specified period of time
  • Causes: Scanning system related service call Carriage home position sensor not going ON within a specified time.
  • Remedy: 1 Carriage locking Check if the carriage locking screw for packaging is attached.
    2 Carriage hole position sensor • Check if the harness is properly connected to the sensor. • Check if the harness is caught or open circuited.
    3 SYS board • Check if the harness (CN121, J002) of the carriage home position sensor is connected properly. • Check if the mounted parts on the SYS board are damaged or abnormal. • Check if 24 V (CM105) on the SYS board is short circuited. • Check if 24 V is supplied to the SYS board (CN105).
    4 Scan motor • Check if the belt tension is loosened (if the motor screw is loosened). • Check if the carriage wire and the timing belt come off. • Check if the connector (CN124) is connected to the motor properly. • Check if the harness of the motor is caught or open circuited.
  • Code: C290
  • Description: Scanner fuse blowout
  • Causes: Scanning system related service call The scanning system does not operate due to a blowout of the fuse in the scanning system.
  • Remedy: Is 24V supplied to the SYS board?
    Yes Check the following because the signal for checking 24V on the SYS board is abnormal. • Check if the scanner CPU (IC26) is damaged or abnormal. • Check if the mounted parts on the SYS board are damaged or abnormal. • Check if 24V on the SYS board is short circuited. • Check if 24V is supplied to the SYS board (CN125).
    No • Check if the 24V supply harness is properly connected to the connector (CN125). • Check if 24V and SG on the SYS board are short circuited. • Check if the power supply is short circuited by pulling out the supply harness on the SYS board (CN125). • Check if the fuse on the LVPS (F203) is open circuited. • Check if there is no abnormality on the LVPS.