PrintCopy.info service

Toshiba e-Studio 2307

Error Codes List page 1

  • Code: C010
  • Description: Drive system related service call Main motor abnormality: The main motor is not rotating normally
  • Causes: Main motor MAIN board
  • Remedy: 1 Is the main motor working? (Perform the output check in the test mode: 03-101/151) Yes 2 No 1. Check if the connector CN1 of the main motor is disconnected. 2. Check if the connector CN19 on the MAIN board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor patterns on the main motor board and MAIN board are short circuited or open circuited. 5. Replace the main motor. 2 Are there any damage or scratches on the main motor board? Yes 3 No 1. Check if the connector pins are disconnected and the harnesses are open circuited. 2. Check if the conductor patterns on the main motor board and MAIN board are short circuited or open circuited. 3. Replace the main motor. 3 MAIN board 1. Check if the PLL lock signal CN19-7 output from the MAIN board is always level “L”? 2. Replace the MAIN board.
  • Code: C040
  • Description: PFP motor abnormality: The PFP motor is not rotating normally.
  • Causes: PFP motor PFP board MAIN board
  • Remedy: 1 Is the PFP motor working? (Perform the output check in the test mode: 03-109/ 159) Yes 2 No 1. Check if the signal line connector CN502, CN503 of the PFP motor is disconnected. 2. Check if the connector CN411 on the PFP board is disconnected. 3. Check if the connector CN410 on the PFP board is disconnected. 4. Check if the connector CN26 on the MAIN board is disconnected. 5. Check if the connector pins are disconnected and the harnesses are open circuited. 6. Check if the conductor patterns on the PFP motor board, PFP board and MAIN board are short circuited or open circuited. 7. Replace the PFP motor. 8. Replace the PFP board. 9. Replace the MAIN board. 2 Is the LED on the PFP motor board lit without flickering? Yes 3 No 1. Check if the connector pins are disconnected and the harnesses are open circuited. 2. Check if the conductor patterns on the PFP motor board, PFP board and MAIN board are short circuited or open circuited. 3. Replace the PFP motor. 4. Replace the PFP board. 5. Replace the MAIN board. 3 PFP board MAIN board 1. Check if the PLL lock signal CN411-8 output from the PFP board is always “L” level. 2. Check if the voltage supplied to the microcomputer input terminal IC5-17 is always “L” level. 3. Replace the PFP board. 4. Replace the MAIN board.
  • Code: C150
  • Description: PFP upper drawer tray abnormality: The PFP upper drawer tray motor is not rotating or the PFP upper drawer tray is not moving normally.
  • Causes: PFP board MAIN board Tray-up motor Tray-up sensor
  • Remedy: 1 Does the tray go up? (Perform the output check in the test mode: 03-278/ 280) Yes 2 No 1. Check if the connector of the tray-up motor is disconnected. 2. Check if any of the connectors CN410, CN413 on the PFP board is disconnected. 3. Check if the connector CN26 on the MAIN board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the PFP board and MAIN board are short circuited or open circuited. 6. Replace the PFP board. 7. Replace the MAIN board. 2 Is the tray-up sensor working? (Perform the input check in the test mode: 03-[1]/ [G], 03-[2]/[E]) Yes 3 No 1. Check if the connector of the sensor is disconnected. 2. Check if any of the connectors CN410, CN414 and CN415 on the PFP board is disconnected. 3. Check if the connector CN26 on the MAIN board is disconnected. 4. Check if the slit reaches the sensor. 5. Check if the connector pins are disconnected and the harnesses are open circuited. 6. Check if the conductor patterns on the PFP board and MAIN board are short circuited or open circuited. 7. Replace the PFP board. 8. Replace the MAIN board. 3 MAIN board 1. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 2. Replace the MAIN board.
  • Code: C160
  • Description: PFP lower drawer tray abnormality: The PFP lower drawer tray motor is not rotating or the PFP lower drawer tray is not moving normally.
  • Causes: PFP board MAIN board Tray-up motor Tray-up sensor
  • Remedy: 1 Does the tray go up? (Perform the output check in the test mode: 03-278/ 280) Yes 2 No 1. Check if the connector of the tray-up motor is disconnected. 2. Check if any of the connectors CN410, CN413 on the PFP board is disconnected. 3. Check if the connector CN26 on the MAIN board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the PFP board and MAIN board are short circuited or open circuited. 6. Replace the PFP board. 7. Replace the MAIN board. 2 Is the tray-up sensor working? (Perform the input check in the test mode: 03-[1]/ [G], 03-[2]/[E]) Yes 3 No 1. Check if the connector of the sensor is disconnected. 2. Check if any of the connectors CN410, CN414 and CN415 on the PFP board is disconnected. 3. Check if the connector CN26 on the MAIN board is disconnected. 4. Check if the slit reaches the sensor. 5. Check if the connector pins are disconnected and the harnesses are open circuited. 6. Check if the conductor patterns on the PFP board and MAIN board are short circuited or open circuited. 7. Replace the PFP board. 8. Replace the MAIN board. 3 MAIN board 1. Check if the conductor pattern on the MAIN board is short circuited or o
  • Code: C260
  • Description: Scanning system related service call. Peak detection error: Lighting of the exposure lamp (white reference) is not detected when power is turned ON.
  • Causes: CIS harness CIS When replacing the CIS, be sure to perform the light volume adjustment (05-3219). MAIN board When replacing the board, be sure to perform the light volume adjustment (05-3219). Scan motor
  • Remedy: 1 Is the exposure lamp lit? Yes It is lit. 2 No It is not lit. 3 2 1. Shading correction plate 1. Check if there is any scratch or stain on the shading correction plate. 2. CIS 1. Perform the light volume adjustment (05-3219). 2. Check if the harness of the CIS is connected properly. 3. Check if the harness is scratched or open circuited. 3. MAIN board 1. Check if the harness of the MAIN board is connected properly. 2. Check if 3.3 V on the MAIN board is short circuited. 3. Check if 3.3 V is supplied to the MAIN board. 4. Check if the mounted parts on the MAIN board are damaged or abnormal. 4. Scan motor 1. Check if the belt tension is loosened. 2. Check if the harness of the motor is caught or open circuited. 3 1. CIS 1. Perform the light volume adjustment (05-3219). 2. Check if the harness of the CIS is connected properly. 3. Check if the harness is scratched or open circuited. 2. MAIN board 1. Check if the harness of the MAIN board is connected properly. 2. Check if 24 V on the MAIN board is short circuited. 3. Check if 24 V is supplied to the MAIN board. 4. Check if 3.3 V on the MAIN board is short circuited. 5. Check if 3.3 V is supplied to the MAIN board. 6. Check if the mounted parts on the MAIN board are damaged or abnormal.
  • Code: C270
  • Description: Scanning system related service call. Carriage home position cannot be detected within a specified period of time: The carriage does not shift from its home position in a specified period of time
  • Causes: CIS harness CIS When replacing the CIS, be sure to perform the light volume adjustment (05-3219). MAIN board When replacing the board, be sure to perform the light volume adjustment (05-3219). Scan motor
  • Remedy: 1 Does the carriage shift from its home position? (Output check: 03-261) Yes It shifts. 2 No It does not shift. 3 2 1. CIS 1. Check if the light source of the CIS lights up while the carriage is shifting to the left. 2. Check if the harness of the CIS is connected properly. 3. Check if the harness is scratched or open circuited. 2. MAIN board 1. Check if the harness of the MAIN board is connected properly. 2. Check if 24 V on the MAIN board is short circuited. 3. Check if 24 V is supplied to the MAIN board. 4. Check if 3.3 V on the MAIN board is short circuited. 5. Check if 3.3 V is supplied to the MAIN board. 6. Check if the mounted parts on the MAIN board are damaged or abnormal. 3. Scan motor 1. Check if the belt tension is loosened. 2. Check if the harness of the motor is caught or open circuited. 3 1. MAIN board 1. Check if the harness of the MAIN board is connected properly. 2. Check if 24 V on the MAIN board is short circuited. 3. Check if 24 V is supplied to the MAIN board. 4. Check if 3.3 V on the MAIN board is short circuited. 5. Check if 3.3 V is supplied to the MAIN board. 6. Check if the mounted parts on the MAIN board are damaged or abnormal. 2. Scan motor 1. Check if the belt and the pulley come off. 2. Check if the harness of the motor is caught or open circuited.