Error Codes List page 1
|
|
- Code: A0-01
- Description: PCU PWB ROM error
- Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. ROM trouble.
- Remedy: Use SIM49-1 to perform the version-up procedure again. Replace the ROM.
- Code: A0-02
- Description: SCU PWB ROM error
- Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. ROM trouble.
- Remedy: Use SIM49-1 to perform the version-up procedure again. Replace the ROM.
- Code: A0-04
- Description: ACU PWB ROM error (when scanner expansion kit is installed)
- Causes: The firmware update is failed because of turning OFF the power during the firmware update operation, etc. ROM trouble.
- Remedy: Use SIM49-1 to execute update of the firmware. Replace the ROM.
- Code: A0-15
- Description: DSK BOOT version disagreement
- Causes: Firmware combination error between the DSK and the BOOT.
- Remedy: Check the combination between the DSK and the BOOT.
- Code: A0-17
- Description: Inconsistency between the UI data and the CPU firmware version
- Causes: Combination error between the UI contents data and the CPU UI firmware version.
- Remedy: Install the firmware in the all firmware version up mode.
- Code: A0-20
- Description: Conflict firmware and EEPROM data version (MFP)
- Causes: Inconsistency between the MFP firmware version and the EEPROM data version.
- Remedy: Check the combination of the firmware.