- Code: U9-84
- Description: Panel board communication trouble (Framing).
A framing error occurs in communication between the MCU and the Panel PWB.
- Causes: MCU PWB - Panel PWB harness trouble/ Garbled data.
- Remedy: MCU PWB - Panel PWB harness trouble. Replace the panel or the MCU PWB. Machine reset (Power OFF/ON).
- Code: U9-88
- Description: Panel board communication trouble (Time out).
A time-out error occurs in communication between the MCU and the Panel PWB.
- Causes: A command is completely sent from the MCU to the panel.
- Remedy: MCU PWB - Panel PWB harness trouble. Replace the panel or the MCU PWB. Machine reset (Power OFF/ON).
- Code: U9-99
- Description: Panel language error.
Language discrepancy error.
- Causes: Discrepancy between the machine language and the panel language.
- Remedy: Replace the panel or the MCU PWB. Reset the machine. (Power OFF/ON).