  • Code: U2-11
  • Description: Counter check sum error (EEPROM)
  • Causes: EEPROM abnormality
  • Remedy: Check that the EEPROM is properly set.
    Use SIM 16 to cancel the trouble.
    Replace the MCU PWB.
  • Code: U2-12
  • Description: Adjustment value check sum error (EEPROM)
  • Causes: EEPROM abnormality
  • Remedy: Check that the EEPROM is properly set.
    Use SIM 16 to cancel the trouble.
    Replace the MCU PWB.