- Code: U2-11
- Description: Counter check sum error (EEPROM)
- Causes: EEPROM abnormality
- Remedy: Check that the EEPROM is properly set.
Use SIM 16 to cancel the trouble.
Replace the MCU PWB.
- Code: U2-12
- Description: Adjustment value check sum error (EEPROM)
- Causes: EEPROM abnormality
- Remedy: Check that the EEPROM is properly set.
Use SIM 16 to cancel the trouble.
Replace the MCU PWB.