- Code: L4 01
- Description: Main motor lock
- Causes: When the main motor encoder pulse is not detected for 100msec.
- Code: L6 10
- Description: Polygon motor lock
- Causes: The lock signal (specified rpm signal) does not return within a certain time (about 20sec) from starting the polygon motor rotation
- Code: U2 01
- Description: Counter sum check error
- Causes: When the counter check sum value stored in the EEPROM is abnormal.
- Code: U2 04
- Description: EEPROM serial communication error
- Causes: When a communication trouble occurs with the EEPROM.