PrintCopy.info service

Sharp AL1651CS

Error Codes List page 4

  • Code: L4-01
  • Description: Main motor lock detection
    When the main motor encoder pulse is not detected for 100 msec.
  • Causes: Main motor unit abnormality Improper connection or disconnection the main motor and the harness. MCU PWB abnormality
  • Code: L6-10
  • Description: Polygon motor lock detection
    The lock signal (specified rpm signal) does not return within a certain time (about 20 sec) from starting the polygon motor rotation.
  • Causes: Polygon motor unit abnormality Improper connection or disconnection of the polygon motor and the harness. MCU PWB abnormality
  • Code: U2-04
  • Description: EEPROM read/write error (Serial communication error)
    EEPROM access process error
  • Causes: EEPROM abnormality
  • Code: U9-99
  • Description: Operation panel language error
    There is no language file. The language file is destroyed
  • Causes: Language file abnormality MCU PWB abnormality