  • Code: 01-015
  • Display: Paper jam at the top of duplex path
  • Description: 1. At Power On, if the Fuser Exit Sensor and/or Reverse Sensor detects paper. 2. At Printing, Fuser Exit sensor and Reverse Sensor is not on within a predetermined time after paper moves into the Reverse path.
  • Causes: 1. Check the Fuser Exit Sensor, Reverse Sensor Harness and Connector. 2. Check if the UI message is changed in the Fuser Exit Sensor and the Reverse Sensor operation (EDC Mode). 3. Check the Reverse Motor and Fuser Exit Motor. (EDC Mode).
  • Remedy: 1. Lift the Scan Unit and Open the Reverse Top Cover and the Middle Open Cover. Check for Paper in the Fuser and Reverse Unit. 2. If the paper is jammed, remove the paper in the Fuser. 3. If the paper is not present, check if the Fuser Exit and Reverse actuator’s return action as the EDC Mode just checks on/off. If so, check the actuator springs of the Fuser Exit and Reverse return spring tension is sufficient,. and sensor arm works smoothly. ( EDC Mode -> Test Routines -> Engine Diagnostic Test -> 102-370 / 102-xxx) 4. If the Actuator Arm in the Fuser and Reverse is Operating properly. Check if Reverse motor and Fuser Exit Motor is turning properly in EDC Mode. ( EDC Mode -> Test Routines -> Engine Diagnostic Test -> 100-xxx / 100-xxx)
  • Code: 01-017
  • Display: Output bin Full Output bin Full. Remove printed paper
  • Description: When the tray limit is reached, the out-bin full sensor is on for 600ms.
  • Causes: 1. Check the Out-Bin Full Sensor. 2. Check if the UI message is changed by the Out-Bin Full Sensor operation. 3. Check the Out-Bin Full Sensor Harness and Connector.
  • Remedy: 1. Check the BIN_FULL_SENSOR (picture’1’ below) by pushing the trigger (picture’2’ below) beneath the SCAN_ ASSY. Check if the UI message is changed by the Out-Bin Full Sensor operation 2. Check if the Harness is defective. Check if the connector is connected properly. 3. Replace the Main PBA or the Scan_Joint PBA or the Panel PBA. 4. Enter the EDC mode and follow the below sequence after the repair is done. ( EDC Mode - Test Routines - 101-Clutch - 0190-OutBin Full - Start - Status check - Stop )
  • Code: 02-000
  • Display: Fuser Error :#02-000 Please turn off then on.
  • Description: At Warm-up, this error has occurred. The machine does not work until power off/on. If the error code reoccurs, follow the Troubleshooting method below
  • Causes: Fuser Unit is not installed and AC is not supplied to the Heat Lamp.
  • Remedy: 1. Turn off the power. And turn on the power. 2. If the problem persists, replace the fuser unit. 3. If the problem persists after replacing the fuser unit, reconnect the CN35 connector on Main-PBA. 4. If the problem persists, replace the Main-PBA.
  • Code: 02-001, 02-006
  • Display: Fuser Error :#02-001 Please turn off then on. Fuser Error :#02-006 Please turn off then on.
  • Description: At Warm-up, this error has occurred. The machine does not work until power off/on. If the error code reoccurs, follow the Troubleshooting method below.
  • Causes: Fuser Unit is not installed and AC is not supplied to the Heat Lamp.
  • Remedy: 1. Turn off the power. And turn on the power. 2. Check the connection of the Fuser AC on FDB 3. Check the Fuser control harness 4. Check the resistance value of the thermostat. If the value is infinite, replace the thermostat. 5. If the problem persists, replace the Fuser unit. 6. Replace the SMPS board or FDB (Fuser drive board).
  • Code: 02-002
  • Display: System Error :#02-002 Please turn off then on.
  • Description: The fuser unit is overheated. The machine does not work until power off/on. If the error code reoccurs, follow the Troubleshooting method below.
  • Causes: The machine can not control fuser temperature.
  • Remedy: 1. Turn off the power. And turn on the power. 2. Replace the Fuser unit. 3. Replace the FDB. 4. Replace the Main-PBA.
  • Code: 02-005
  • Display: System Error :#02-005 Please turn off then on.
  • Description: The ADC port is short.
  • Causes: The machine can not control fuser temperature.
  • Remedy: 1. Turn the power off then on again. 2. If the problem persists, replace the Main PBA.
Error Code