Description: Tool / Crop Error This error occurs when the machine performs the Auto Crop Mark Detection or the Auto Print / Cut adjustment without the Tool / Crop Mark Sensor Adjustment.
Causes: Tool / Crop Mark Sensor Adjustment has not been performed.
Remedy: 1 ) Tool / Crop Mark Sensor Adjustment
Code: Err
Description: The SV or the set values of some parameters have been changed without any operation.
Causes: Parameter settings of [P-SL], [P-SU] and [P-n2] are not correct. Parameter settings of [P-SL], [P-SU] and [P-n2] are not correct. When the set value of [P-SU] is larger than 1000, "1" will be registered for [P-DP].
Remedy: Set the parameter of [P-SL] to 0, [P-SU] to 150 and [P-n2] to 1.
Code: UUUU, LLLL
Description:
Causes: Parameter setting of [P-n2] is not correct. The Cable of the Thermistor which is fixed to the Controller is broken or short-circuit. The Cable of the Thermistor which is fixed to the Controller is loose. The Thermistor is broken. Parameter settings of [P-SL], [P-SU] and [P-n2] are not correct.
Remedy: Set the parameter of [P-n2] to 1. Replace the Thermistor Cable. Check the Cable Connection. Replace the Thermistor Cable. Set the parameter of [P-SL] to 0, [P-SU] to 150 and [P-n2] to 1.