  • Code: 0109
  • Description: Wiper unit does not work correctly.
  • Causes: Wiper Motor error
    Defect of Wiper Unit
    Defect of Wiper Sensor
    Cut-line or short-circuit of cable and Flexible cable
  • Remedy: Wiper Motor Replacement
    Wiper Unit Replacement
    Wiper Sensor Replacement
    Cable and Flexible Cable Replacement
  • Code: 0110
  • Description: There is a problem in reading the Linear Encoder.
  • Causes: Read error of Linear Encoder.
    Read error of Encoder on Scan Motor side.
    Belt is not fixed to Head Carriage firmly.
  • Remedy: Confirm whether Encoder Scale is between the slit of Encoder Module in a whole width of the printer.
    Check cable connection between Linear Encoder Board and Head Board
    Confirm connection between Belt and Carriage
    Linear Encoder replacement
    Scan Motor replacement
    Servo Board replacement
    Main Board replacement
  • Code: 0112
  • Description: It is not possible to communicate with the Cartridge IC driver.
  • Causes: Cartridge IC driver has a problem (not working).
    The communication wire of Cartridge IC driver cable has short circuited or cut-line.
  • Remedy: Ink Cartridge IC sensor replacement
  • Code: 0148
  • Description: There is a problem with the Thermistor on the Cyan Head.
  • Causes: There is a bad connection between Cyan Head and Print
    Carriage Board (CN18).
    There is a bad connection between Print Carriage Board (CN2) and Head Board (CN1).
    Cyan Head is broken.
  • Remedy: Check cable connection between Head and Print
    Carriage Board (CN18).
    Check cable connection between Print Carriage Board (CN2) and Head Board (CN1).
    Cyan Head replacement.
  • Code: 0151
  • Description: Head UP/DOWN sensor is OFF although it should be ON. Or, vice versa.
  • Causes: Head UP/DOWN Motor is broken.
    Head UP/DOWN sensor is broken.
    Wiring or Flexible Cable has short circuited or cut-line.
    Servo Board is broken.
  • Remedy: Check the cable connections of Servo Board
    Check the cable connections of Junction Board
    Head UP/DOWN Motor Replacement
    Head UP/DOWN Sensor Replacement
    Cable and Flexible Cable Replacement
    Servo Board Replacement
  • Code: 0210
  • Description: The UV Lamp is not connected / tuned on. It is not possible to communicate with the Maintenance/Front Cover Cable.
  • Causes: There is a bad connection between UV Lamp and Print Carriage Board.
    There is a bad connection between UV Junction Board and DC Junction Board.
    There is a bad connection between DC Junction Board and SW Power Supply.
    There is a bad connection between SW Power Supply and AC Junction Board.
    There is a bad connection between UV Junction Board and AC Junction Board.
    There is a bad connection between UV Junction Board and UV Relay Board.
    There is a bad connection between Step Drive Board and
    Motsens Junction Board.
    There is a bad connection between Motsens Junction
    Board and Grit Encoder Board.
    There is a bad connection between Motsens Junction
    Board and Main Board.
    There is a bad connection between I/S Cover and Motsens Junction Board.
    There is a bad connection between Front Cover / Maintenance Cover and Grit Encoder Board.
    Main Board is broken.
    The UV Lamp is broken.
  • Remedy: Check the lighting of [DC OK] LED on the UV device while the IS Cover Sensor, Front Cover Sensor and Maintenance Cover Sensor is turned on. If it does not light, the UV device itself could be broken.
    Check cable connection between UV Lamp and Print Carriage Board.
    Check cable connection between UV Junction Board and DC Junction Board.
    Check cable connection between DC Junction Board and SW Power Supply.
    Check cable connection between SW Power Supply and AC Junction Board.
    Check cable connection between UV Junction Board and AC Junction Board.
    Check cable connection between UV Junction Board and UV Relay Board.
    Check cable connection between Step Drive Board and Motsens Junction Board.
    Check cable connection between Motsens Junction Board and Grit Encoder Board.
    Check cable connection between Motsens Junction Board and Main Board.
    Check cable connection between I/S Cover and Motsens Junction Board.
    Check cable connection between Front Cover / Maintenance Cover and Grit Encoder Board.
    DC Junction Board replacement
    AC Junction Board replacement
    UV Relay Board replacement
    Motsens Junction Board replacement
    Grit Encoder Board replacement
    SW Power Supply replacement
    Main Board replacement
    UV Lamp replacement