Roland CX500 Camm-1 pro
Error Codes List page 2
|
- Code: 4000
- Description: Command Communication Error.
- Causes: The communication error occurs when the IC4 or IC22 on the Main Board is broken. And it causes the Motor Error.
- Remedy: Replace the Main Board.