  • Code: T96
  • Description: Data not input
  • Causes: 171 TPH resistance not set. 172 Scanner adjustment not completed. 433 Paper width potentiometer (VR) not set. 569 Print drum color or ink category not set. 613 Print pressure compensation not set. 972 REv data storage area not initialized.
  • Remedy: Enter parameters in Test Mode.
  • Code: T97
  • Description: PC card access error
  • Causes: 939 PC card access error: PC card not set. 940 PC card access error: Device information multiple-ID error (PCMCIA card information error). 941 PC card access error: Device error (incompatible CF card error). 942 PC card access error: File creation failed (File with the same name already exists). 943 PC card access error: Unformatted. 944 PC card access error: Media ID error. 945 PC card access error: Media error (CF card cannot be accessed). 946 PC card access error: Insufficient disc capacity (Not enough space available on the CF card to write data). 990 PC card access error: Specified file not found on the selected drive. 991 PC card access error: The file accessed is not currently open. 992 PC card access error: File information storage folder already in use. 993 PC card access error: Incorrect read address setting for data transfer to mechanical unit. 994 PC card access error: File deletion failed.
  • Remedy: Press the Reset key.
  • Code: T98
  • Description: Hardware error
  • Causes: 002 No response from the SH4F PCB. Although SH4F PCB signal is detected at power ON, if no response is received from the SH4F PCB and an T98-069 error is detected, the detected error is rewritten to this error code. 005 Hardware error (Machine model code error). 006 FRAM checksum error. 025 Faulty tag RF PCB (initial communication with the tag RF PCB failed). 034 Unable to write data to the main unit EEPROM (EEPROM cannot be accessed). 035 CRC error generated in the main unit EEPROM (EEPROM data error). 038 The machine model information for the PCB and the EEPROM fail to match. 039 Incorrect EEPROM. 051 Communication error with touch-panel controller. 053 Unsuccessful attempt to read memory parameters (program, mode, user paper). 054 Unsuccessful attempt to write memory parameters (program, mode, user paper). 055 The machine model code sent from the SH-PCB does not correspond to the machine model information in the mechanical control PCB. 064 Communication between SH PCB and mechanical control PCB: Undefined command was issued. 065 Communication error between SH PCB and mechanical control PCB (01) (on mechanical control PCB side): Incorrect number of bytes in received command. 067 Communication error between SH PCB and mechanical control PCB (03) (on mechanical control PCB side): RNK received. 068 Communication error between SH PCB and mechanical control PCB (04) (on mechanical control PCB side): NAK received 3 times. 069 Communication error between SH PCB and mechanical control PCB (05) (on mechanical control PCB side): No ACK response. 070 Communication error between SH PCB and mechanical control PCB (06) (on mechanical control PCB side): Transmission prevented by SH PCB. 071 Communication error between SH PCB and mechanical control PCB (07) (on mechanical control PCB side): Command received while awaiting response. 072 Communication error between SH PCB and mechanical control PCB (08) (on mechanical control PCB side): FB command received in mode other than download mode. 073 Communication error between SH PCB and mechanical control PCB (09) (on mechanical control PCB side): FC/FD command received in mode other than download mode. 074 Communication error between SH PCB and mechanical control PCB (10) (on SH PCB side): FE command received (No mechanical control PCB program). 075 Communication error between SH PCB and mechanical control PCB (11) (on SH PCB side): Incorrect number of bytes in received command. 076 Communication error between SH PCB and mechanical control PCB (12) (on SH PCB side): Received ACK not specified in sequence. 077 Communication error between SH PCB and mechanical control PCB (13) (on SH PCB side): RNK received. 078 Communication error between SH PCB and mechanical control PCB (14) (on SH PCB side): NAK received 3 times. 079 Communication error between SH PCB and mechanical control PCB (15) (on SH PCB side): No ACK response. 080 Communication error between SH PCB and mechanical control PCB (16) (on SH PCB side): Transmission prevented by the mechanical control PCB (CTS = 1). 081 Communication error between SH PCB and mechanical control PCB (17) (on SH PCB side): Mechanical control download mode was transmitted in error. 082 Communication error between SH PCB and mechanical control PCB (18) (on SH PCB side): Mechanical CTS remained at <1> for 2 seconds. 083 Communication error between SH PCB and mechanical control PCB (19) (on SH PCB side): FA command received at time other than startup. 084 Communication error between SH PCB and mechanical control PCB (20) (on SH PCB side): <80> command not received within 10 seconds after power ON. 085 Unsuccessful attempt to read user parameters (administrator settings, Test Mode adjustment values). 086 Unsuccessful attempt to write user parameters (administrator settings, Test Mode adjustment values). 087 No values set for memory parameters (program, mode, user paper). 088 No values set for user parameters (administrator settings, Test Mode adjustment values). 089 The DIP-SW 1 on the SH4F PCB is switched ON (PCB check setting is switched ON). 090 The machine model code in memory parameters (program, mode, user paper) does not match. 091 The checksum for memory parameters (program, mode, user paper) does not match. 092 The machine model code in user parameters (administrator settings, Test Mode adjustment values) does not match. 093 The checksum for user parameters (administrator settings, Test Mode adjustment values) does not match. 094 Communication sequence error between SH PCB and mechanical control PCB. 095 The checksum for user parameters (administrator settings, Test Mode adjustment values) does not match during standby. 096 The checksum for memory parameters (program, mode, user paper) does not match during standby. 097 The Test Mode adjustment value set in the print drum memory lies outside the adjustment range. 098 The machine serial number information in the main unit EEPROM does not correspond to the machine serial number information in the FRAM. 099 SH4F PCB: Undefined interrupt processing was generated. 119 Faulty image PCB (Memory check of the image processing IC failed). (Image processing IC check timing: during initialization) 120 Time-out error generated while awaiting scanner serial communication interrupt command (The CPU failed to receive interrupt command from FORCE device within 100 ms). Scanner serial communication timing: Transmission of data to AK8412 (A/D converter). Transmission of data to scanner gate array. Reading of data from scanner gate array 129 Faulty scanner gate array PCB (Error generated in the memory check of the scanner gate array). 245 Time-out error (action other than sensor standard) for the write pulse motor during master transport in master-making operation. 246 Time-out error (action other than sensor standard) for the load pulse motor during master transport in master-making operation. 422 The DA setting for adjustment of the light-emitting section reached 423 The DA setting for adjustment of the light-emitting section reached the lower-limit value during automatic multiple paper feed sensor adjustment in Test Mode No. 705. 448 The DA setting for adjustment of the light-emitting section reached the upper-limit value during automatic registration sensor adjustment in Test Mode No. 709. 449 The DA setting for adjustment of the light-emitting section reached the lower-limit value during automatic registration sensor adjustment in Test Mode No. 709. 922 SH4F PCB system lock (image communication error). 934 Communication error between mechanical control PCB and tag RF PCB (detection on tag RF PCB side). 935 Communication error between mechanical control PCB and tag RF PCB (detection on mechanical control PCB side). 937 Serial number not set. 938 Old FRAM version. 947 24V-A does not switch ON (possibility of blown 24V-A fuse). 948 24V-B does not switch ON (possibility of blown 24V-B fuse). 949 24V-A does not switch OFF. 950 24V-B does not switch OFF. 952 Checksum error in SH4F PCB flash memory. 953 Error generated during attempt to write data to SH4F PCB flash memory. 960 Error generated during attempt to read data from SH4F PCB flash memory. 961 SH4F PCB flash memory not in use. 978 Illegal power ON command received from the mechanical control PCB at a time other than boot up or wake-up. 979 Abnormal setting value in SH4F PCB flash memory properties. 986 The software for the mechanical control PCB does not match the DSP (main, second) software. Download the DSP software version suitable for the software for the mechanical control PCB. 987 Communication error between DSP and mechanical control PCB. 988 The second paper feed motor parameter and the main motor parameter are <00h>. Main motor parameter acquisition mode and second paper feed motor parameter acquisition mode in Test Mode have not been executed.the upper-limit value during automatic multiple paper feed adjustment in Test Mode No. 705.
  • Remedy: Switch power OFF, then ON.
  • Code: T99
  • Description: Software error
  • Causes: 900 Heart-beat lock error.
  • Remedy: Switch power OFF, then ON.