Causes: • In 3 seconds from turning ON of the Main motor, the A detection sensor light path is still held blocked. • In 8 seconds from turning ON of the Main motor, the A detection sensor is not blocked.
Remedy: Press <ALL RESET> key. Press <START> key.
Code: T10
Description: Malfunction Image Processing PCB
Causes: • When the scanning contrast adjustment signal is not output from the image processing PCB.
Remedy: OFF -> ON
Code: T11
Description: Pressure Control Motor Lock
Causes: • In 100ms from turning ON of the Pressure control motor, the Encoder sensor cannot detect a pulse. • In 5 seconds from turning ON of the Pressure control motor, the Pressure centering sensor is not turned ON/OFF.
Remedy: Press <ALL RESET> key.
Code: T12
Description: CALL SERVICE
Causes: • Malfunction of Trimming PCB • When the TOP signal is not output from the Trimming PCB 2
Remedy: OFF -> ON
Code: T13
Description: Cutter Motor Lock
Causes: • After master cutting retrial with the drum held in C-2 position, when the Master positioning sensor is in light-receiving state. (Master cutting has failed in the 2nd time.)
Remedy: Drawer connector OFF (Pull out the drum.)
Code: T14
Description: Clamp Error (2)
Causes: • If the actuator of the Clamp safety switch is not depressed when the Clamp solenoid is not in operation.