  • Code: P96
  • Description: Data not input
  • Causes: 171 TPH resistance value not input.
  • Remedy: Input the parameters using test mode.
  • Code: P97
  • Description: PC card access error
  • Causes: 9 39 PC card not inserted. 94 0 PC card device data double ID error (data error as PCMCIA card). 94 1 PC device error (not detected as PC card). 94 2 File production error (same file name already exists). 94 3 PC card not formatted correctly. 944 PC card ID error. 94 5 PC card error (detected as PC card, but unable to make access). 946 PC card capacity error (not enough blank area). 99 0 File does not exist in the specified drive. 99 1 Accessed into a non-opened file). 99 2 File pointer to save the data is already in use. 99 3 Read address is not correctly set up. 994 File delete arror (file is not correctly deleted).
  • Remedy: Turn power OFF and ON.
  • Code: P98
  • Description: Hardware error
  • Causes: 002 No reply from optional neoROSA. If neoROSA signal is detected at machine power ON, but if the PCB communication terminates and P98-069 error is detected, the error point is rewrote to this P98-002 error message. 005 Hardware error 006 EEPROM check-sum error 025 Possible defective RF PCB (Unsuccessful initial communication with RF PCB). 034 Unable to write on EEPROM on the machine. (Cannot access EEPROM). 035 CRC error on EEPROM on the machine (Defective EEPROM data). 038 Machine information between the EEPROM and PCB does not match. 039 Incorrect EEPROM. 041 5 volt power not available. Possibility of faulty 5 volt fuse. 045 5 volt power does not go OFF when the machine tries to go into sleep mode. 063 Test mode setting is beyond the adjustable range. 064 Communication error between neoROSA and MCTL PCB. 065 Communication error between neoROSA and MCTL PCB (01) - on MCTL PCB side. 067 Communication error between neoROSA and MCTL PCB (03) - on MCTL PCB side. 068 Communication error between neoROSA and MCTL PCB (04) - on MCTL PCB side. 069 Communication error between neoROSA and MCTL PCB (05) - on MCTL PCB side. 070 Communication error between neoROSA and MCTL PCB (06) - on MCTL PCB side. 071 Communication error between neoROSA and MCTL PCB (07) - on MCTL PCB side. 072 Communication error between neoROSA and MCTL PCB (08) - on MCTL PCB side. 073 Communication error between neoROSA and MCTL PCB (09) - on MCTL PCB side. 074 Communication error between neoROSA and MCTL PCB (10) - on neoROSA side. 075 Communication error between neoROSA and MCTL PCB (11) - on neoROSA side. 076 Communication error between neoROSA and MCTL PCB (12) - on neoROSA side. 077 Communication error between neoROSA and MCTL PCB (13) - on neoROSA side. 078 Communication error between neoROSA and MCTL PCB (14) - on neoROSA side. 079 Communication error between neoROSA and MCTL PCB (15) - on neoROSA side. 080 Communication error between neoROSA and MCTL PCB (16) - on neoROSA side. 081 Communication error between neoROSA and MCTL PCB (17) - on neoROSA side. 082 Communication error between neoROSA and MCTL PCB (18) - on neoROSA side. 083 Communication error between neoROSA and MCTL PCB (19) - on neoROSA side. 084 Communication error between neoROSA and MCTL PCB (20) - on neoROSA side. 098 Machine serial number information does not match between the backup data and EEPROM. 119 Defective image PCB (memory check error on the image processing IC). 121 Scanner adjustment error (IFLG does not change within set time). 122 Scanner adjustment error (IMFLGdoes not change within set time). 245 Timeout error on master transfer during master-making (related to Write pulse motor). 9 21 USB controller chip does not reply. May need to replace neoROSA. 9 34 Communication error between MCTL PCB and RF PCB. (on RF PCB side) 9 35 Communication error between MCTL PCB and RF PCB. (on MCTL PCB side) 9 37 Serial number not set. 9 38 EEPROM version down. 947 24V-A does not go ON. (possibility of 24v fuse broken on A-series) 94 8 24V-B does not go ON. (possibility of 24v fuse broken on B-series) 949 4 2V-A does not go OFF. 9 50 4 2V-B does not go OFF. 9 52 Check-sum error on neoROSA PCB flash memory. 9 53 Write error on the neoROSA PCB flash memory. 96 0 Read error on the neoROSA PCB flash memory. 96 1 Flash memory on neoROSA PCB not used.
  • Remedy: Turn power OFF and ON.
  • Code: P99
  • Description: Software error
  • Causes: 509 Master-loading sensor was OFF when the master was checked at a specified drum angle during the master-loading operation.
  • Remedy: Pull out the print cylinder and set it back.