Description: Scanner image data transfer error
The image transfer from the engine to the controller via the PCI bus does not end within 3 s after starting.
Causes: • Controller board defective • BICU defective • Connectors between BICU and controller loose or defective • SIB defective
Code: 986
Description: Software write parameter setting error
An unstable area at the storage destination in the settings table is set NULL for the parameter received by the write module.
Causes: • Software defective
Code: 990
Description: Software error 1
The software performs an unexpected function and the program cannot continue.
Causes: • Software defective, re-boot
Code: 991
Description: Software error 2
The software performs an unexpected function. However, unlike SC990, recovery processing allows the program to continue.
Causes: • Software defective, re-boot
Code: 995
Description: Machine Type Information Error
After the machine is powered on, a mismatch is detected between the CPM information sent from the controller to the engine. The controller board was replaced with the incorrect type of controller board.
Causes: • Replace the controller board with the correct type of board.
Code: 996
Description: FCU Board Error
The FCU board is installed but it has not entered READY status.