PrintCopy.info service

Ricoh MP2000

Error Codes List page 13

  • Code: 955
  • Description: Image transfer error
    The controller is not able to transfer images when the engine needs them.
  • Causes: - Application program defective
  • Code: 964
  • Description: Status error (laser optics housing unit)
    The optics-housing unit does not become ready within 17 seconds after the request.
  • Causes: - Software defective
  • Code: 981
  • Description: NVRAM error
    The machine detects a discrepancy in the NVRAM write/read data when attempting to save actual data to the NVRAM (i.e. during actual use).
  • Causes: - NVRAM defective
    - Poor connection between BICU and NVRAM
    - NVRAM is not connected
    - BICU defective
  • Code: 982
  • Description: Localization error
    The localization settings in the nonvolatile ROM and RAM are different
  • Causes: - First machine start after the NVRAM is replaced
    - Incorrect localization setting
    - NVRAM defective
  • Code: 984
  • Description: Print image transfer error
    Print images are not transferred.
  • Causes: - Controller defective
    - BICU board defective
    - Poor connection between controller and BICU
  • Code: 990
  • Description: Software performance error
    The software attempted to perform an unexpected operation
  • Causes: - Software defective
    - Internal parameter incorrect
    - Insufficient working memory
    - When this SC occurs, the file name, address, and data will be stored in NVRAM. This information can be checked by using SP 7403. Note the above data and the situation in which this SC occurs. Then report the data and conditions to your technical control center.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files