PrintCopy.info service

Ricoh M0CH P801

Error Codes List page 24

  • Code: SC995-03
  • Description: CPM setting error 3
    Comparison of machine serial number (11 digits) and machine identification code.
    Details:
    Unable to recognize machine identification code because the controller was replaced
    incorrectly or is malfunctioning.
  • Causes: Machine serial number (11 digits) or machine identification code does not match.
  • Remedy: Replace it with the correct type of controller.
  • Code: SC995-04
  • Description: CPM setting error 4
    Comparison of machine serial number (11 digits) and machine identification code.
  • Causes: Machine serial number (11 digits) or machine identification code does not match.
  • Remedy: Return the parts to the original configuration, and then replace them according to the manual
  • Code: SC997-00
  • Description: Application function selection error
    • No response to the predetermined command from SCS to the same
    application program 4 times consecutively.
    Cases when SC997-00 occur;
    1. SCS sends a command to the copy application.
    2. There has been no response from the copy application for 30 sec. (Error count value: 1)
    3. Step1-2 is repeatedly performed 3 times. (Error count value: 4)
    4. SC997-00 occur.
    Cases when SC997-00 does not occur;
    1. SCS sends a command to the copy application.
    2. There has been no response from the copy application for 30 sec. (Error
    count value: 1)
    Step1-2 is repeatedly performed 2 times. (Error count value: 4)
    3. SCS sends a command to the copy application.
    There has been a response from the copy application. (Error count value: 1)
    • The application ended by an unusual process
  • Causes: A software bug (mainly the application)
  • Remedy: • Check the optional RAM/DIMM/boards required by the application program.
    • Check if the combination of downloaded programs is correct.
  • Code: SC998-00
  • Description: Application start error
    • No application was registered to the system within a specified time after the main power was turned ON. (No application starts/All applications have been terminated abnormally)
    • The application started but cannot be drawn now for some reason.
  • Causes: • A software bug (mainly the application)
    • The optional RAM/DIMM/boards, required by the application program, are not installed correctly.
  • Remedy: • Check the optional RAM/DIMM/boards required by the application program.
    • Check if the combination of downloaded programs is correct.
    • Replace the controller board (PCB15).
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us