Remedy: 1. Turn the main switch off and on. 2. Reinstall the controller and/or engine main firmware. 3. See NOTE 1 at the end of the SC table.
Code: SC998
Description: Application start error No applications start within 60 seconds after the power is turned on.
Causes: • Loose connection of RAM-DIMM, ROMDIMM • Defective controller • Software problem
Remedy: 1. Turn the main switch off and on. 2. Check if the RAM-DIMM and ROMDIMM are properly connected. 3. Reinstall the controller system firmware. 4. Replace the controller.